Position trimming and position offset

The position offset is transferred to the drive axis via a profile generator. The offset is specified via the following parameters:
–
Internal position offset 0x5041:053
 
–
Control word 4 of the fieldbus data interface. 0x5040:023
 
Bit 23 of the Control signals parameter is used for switch-over between the sources. 0x5040:010 Bit 23
 
Fig. 1: Trimming
Fig. 2: Partial signal flow - trimming
Position trimming is only possible in the engaged state.
–
The control word bit 20 = TRUE activates a positive direction of rotation. 0x5040:010
 
–
The control word bit 21 = TRUE activates a negative direction of rotation. 0x5040:010
 
 
The following parameters set the acceleration, maximum velocity and deceleration for positioning:
Trimming - position difference 0x5041:024
Trimming - velocity 0x5041:025
Trimming - acceleration 0x5041:026
Trimming - deceleration 0x5041:027
Trimming - velocity offset 0x5041:028
The Trimming position offset parameter identifies the trimming as a proportion of the total offset. 0x5042:027
 
The master axis values overlay the trimming acceleration and velocity. This results in the following values for the axis to be trimmed:
Resulting velocity and resulting acceleration
VARes
Resulting axis velocity
aARes
Resulting axis acceleration
VL
Master axis velocity
aL
Master axis acceleration
Trimming - velocity
Trimming - acceleration
 
The Compensation permissible direction parameter defines the direction of rotation of the drive:
Parameter name
Parameter index
Bit
Function
Offset direction allowed
0x5041:022
0
Both directions of rotation possible
Offset direction allowed
0x5041:022
1
Direction of rotation in master value direction of rotation
 
Fig. 3: Direction of rotation only in master direction of rotation (eOffsetDirection = 1)
The illustration shows the response when the axis is permitted to rotate in the positive and negative directions and the parameter Offset direction allowed  = 0 (both). 0x5041:022
Fig. 4: Direction of rotation in positive and negative direction (eOffsetDirection = 0)
Every 3 seconds, the position compensation in the Offset direction allowed parameter switches between 40 and 80 units. 0x5041:022
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5040:023
External position offset
-214748.3648 ... [0.0000] ... 214748.3647
Value for the external position offset.
0x5041:023
Trimming - Reset offset
false
FALSE
true
TRUE
0x5041:024
Trimming - Position difference
0.0000 ... [1.0000] ... 214748.3647
0x5041:025
Trimming - Velocity
-214748.3648 ... [50.0000] ... 214748.3647
0x5041:026
Trimming - Acceleration
-21474836.48 ... [100.00] ... 21474836.47
0x5041:027
Trimming - Deceleration
-21474836.48 ... [100.00] ... 21474836.47
0x5041:028
Trimming - Jerk
-21474836.48 ... [10000.00] ... 21474836.47
0x5041:053
Internal position offset
-214748.3648 ... [0.0000] ... 214748.3647
0x5041:058
Load position offset
false
FALSE
true
TRUE
0x5042:021
Set velocity after measuring system alignment
–
Read only
 
0x5042:025
Active position offset
–
Read only
 
0x5042:027
Trimming - Position offset
–
Read only
 
0x5042:029
Total position offset
–
Read only
 
0x5042:030
Total velocity offset
–
Read only