Master value correction (register control)

General function
The master value correction is a superimposed control loop. A master position value is calculated based on the master velocity and with the aid of marks. This closed loop control makes it possible to compensate for mark offsets on the material, with reference to the master position. The cycle length of this corrected master position value, which corresponds to the distance between the marks (register cycle), is specified in the Mark distance parameter. 0x5041:002
 
The Sensor distance parameter specifies the distance between the mark sensor and the position where the tool starts on the material. 0x5041:001
The Sensor distance parameter defines the position of the sensor in the Set sensor position parameter within the register cycle.
–
Sensor distance 0x5041:001
 
–
Sensor set position 0x5042:001
 
 
If a mark occurs in the process, the detected register position will be compared with the sensor position. The positions generate a difference:
Difference positions
–
Sensor set position 0x5042:001
 
–
Actual mark position 0x5042:002
 
The difference between Set sensor position and Mark current position is the position error Actual mark error. 0x5042:003
Fig. 1: Master value correction partial signal flow
 
Relevant parameters of other functions
Address
Name
Default setting
Setting range
TP1 source
Digital input 1, positive edge [1]
Selection list
Sensor distance
360.0000
0.0000 ... 214748.3647
Mark distance
360.0000
0.0001 ... 214748.3647
Max. positive correction
45.0000
0.0000 ... 214748.3647
Max. negative correction
45.0000
0.0000 ... 214748.3647
Reference measuring system of correction window
Corrected master position [1]
Selection list
Upper correction position
350.0000
0.0000 ... 214748.3647
Lower correction position
200.0000
0.0000 ... 214748.3647
Mark window size
40.0000
0.0000 ... 214748.3647
Mark window offset
0.0000
0.0000 ... 214748.3647
Max. number of missed marks
20
0 ... 4294967295
Gearbox factor correction gain
0.1000
0.0000 ... 214748.3647
Max. gearbox factor correction
10.0000
0.0000 ... 214748.3647
Activate master value correction
0
Mark error compensation dead time
0.000 ms
-2147483.648 ... 2147483.647 ms
Sensor set position
- (Read only)
Actual mark position
- (Read only)
Actual mark error
- (Read only)
Actual limited mark error
- (Read only)
Actual gearbox factor
- (Read only)
Corrected set position
- (Read only)
Corrected set velocity
- (Read only)
Set position of selected master value
- (Read only)
Set velocity of selected master value