Master value correction (register control)
General function
The master value correction is a superimposed control loop. A master position value is calculated based on the master velocity and with the aid of marks. This closed loop control makes it possible to compensate for mark offsets on the material, with reference to the master position. The cycle length of this corrected master position value, which corresponds to the distance between the marks (register cycle), is specified in the Mark distance parameter.
0x5041:002
0x5041:002The Sensor distance parameter specifies the distance between the mark sensor and the position where the tool starts on the material.
0x5041:001
0x5041:001The Sensor distance parameter defines the position of the sensor in the Set sensor position parameter within the register cycle.
If a mark occurs in the process, the detected register position will be compared with the sensor position. The positions generate a difference:
The difference between Set sensor position and Mark current position is the position error Actual mark error.
0x5042:003
0x5042:003Fig. 1: Master value correction partial signal flow
Relevant parameters of other functions
|
Address
|
Name
|
Default setting
|
Setting range
|
|
TP1 source
|
Digital input 1, positive edge [1]
|
Selection list
|
|
|
Sensor distance
|
360.0000
|
0.0000 ... 214748.3647
|
|
|
Mark distance
|
360.0000
|
0.0001 ... 214748.3647
|
|
|
Max. positive correction
|
45.0000
|
0.0000 ... 214748.3647
|
|
|
Max. negative correction
|
45.0000
|
0.0000 ... 214748.3647
|
|
|
Reference measuring system of correction window
|
Corrected master position [1]
|
Selection list
|
|
|
Upper correction position
|
350.0000
|
0.0000 ... 214748.3647
|
|
|
Lower correction position
|
200.0000
|
0.0000 ... 214748.3647
|
|
|
Mark window size
|
40.0000
|
0.0000 ... 214748.3647
|
|
|
Mark window offset
|
0.0000
|
0.0000 ... 214748.3647
|
|
|
Max. number of missed marks
|
20
|
0 ... 4294967295
|
|
|
Gearbox factor correction gain
|
0.1000
|
0.0000 ... 214748.3647
|
|
|
Max. gearbox factor correction
|
10.0000
|
0.0000 ... 214748.3647
|
|
|
Activate master value correction
|
0
|
|
|
|
Mark error compensation dead time
|
0.000 ms
|
-2147483.648 ... 2147483.647 ms
|
|
|
Sensor set position
|
- (Read only)
|
||
|
Actual mark position
|
- (Read only)
|
||
|
Actual mark error
|
- (Read only)
|
||
|
Actual limited mark error
|
- (Read only)
|
||
|
Actual gearbox factor
|
- (Read only)
|
||
|
Corrected set position
|
- (Read only)
|
||
|
Corrected set velocity
|
- (Read only)
|
||
|
Set position of selected master value
|
- (Read only)
|
||
|
Set velocity of selected master value
|
- (Read only)
|
||