Position correction
The position correction takes place within a correction window.
The position of this window is specified via the parameters Upper correction position and Lower correction position.
The position is set in the unit of the measuring system used.
The Reference measuring system of correction window parameter specifies whether the position of the correction window relates to the corrected master position or the position of the drive axis.
0x5041:005
0x5041:005|
Parameter index
|
Selection in the parameter
|
Information
|
Figure
|
|
Correction master position (1)
|
Correction window relates to the position of the drive axis.
|
||
|
Current tool position (2)
|
Correction window relates to the position of the corrected master axis.
|
The determined position error can be limited to a maximum value. This keeps accelerations low during the corrective movement, for instance. In order to limit the maximum value, there is one parameter available for both the positive limit value and the negative limit value.
Parameters for limit values
–
Max. positive correction
0x5041:003
0x5041:003–
Max. negative correction
0x5041:004
0x5041:004The limited position error is displayed in the Actual limited mark error parameter.
0x5042:004
0x5042:004The resulting position and velocity of the corrected master value can be found in the parameters Corrected setpoint position and Corrected setpoint velocity.
Parameter
0x5041:005