Gearbox factor correction
Modified register properties lead to a changed, real register length. The difference to the parameterised register length Sensor distance leads to corrections in always the same direction (positive or negative).
0x5041:001
0x5041:001This correction is inefficient and leads to increased energy consumption and increased mechanical stress. The gearbox factor correction calculates the optimum setpoint velocity of the master value in this case.
The correction value is determined from the mean value of the position errors. The correction value affects the setpoint velocity of the master value axis. When the gearbox factor is adjusted, the constant part of the position errors is eliminated and the correction is made in the positive and negative directions.
If the selected gain is too high, this can lead to an excessive setpoint velocity.
|
Parameter name
|
Parameter index
|
Status
|
Function
|
|
Activation of gearbox factor correction
|
TRUE
|
Activates gearbox factor correction
|
|
|
Gearbox factor correction gain
|
-
|
Affects the velocity at which the gearbox factor correction adjusts the static error
|
|
|
Actual gearbox factor
|
-
|
Outputs the value of the gearbox factor
|
|
|
Max. gearbox factor correction
|
-
|
Specifies the maximum value of the gearbox factor correction
|
When the corrected gearbox factor has been detected, corrective movements occur in the positive and negative directions. The detected gearbox factor is permanently accepted with bit 25 = TRUE of the Activation of gearbox factor correction parameter.
0x5041:016
0x5041:016If the parameter Activation of gearbox factor correction = FALSE, the value of the gearbox factor can be modified.
0x5041:016
0x5041:016|
Address
|
Name / setting range / [default setting]
|
Info
|
|
|
0x5041:016
|
Activate gearbox factor correction
|
|
|
|
Bit 0
|
FALSE
|
Gearbox factor correction deactivated
|
|
|
Bit 1
|
TRUE
|
Gearbox factor correction activated
|
|
Parameter