Feedback system for the technology application

If the "Application feedback (B)" setting is selected as the master value source, the master value will be provided by the optional slot (B) of the device.0x500B:010
Fig. 1: Slot (B)
Fig. 2: Application feedback (B) as master value source
 
The technology application responds to encoder errors of the application feedback (B). The error response is configured in the Load encoder/master encoder error response parameter. 0x2C55
Fig. 3: Basic signal flow for error response to the virtual master
 
The Load encoder/master encoder error response parameter displays the following errors. 0x2C55
Setting
Response
Parameter index
Load encoder/master encoder error response = [0] no response
No response
-
Load encoder/master encoder error response = [1] fault
The drive changes to the error status ErrorStop.
Note:
If the technology application serves as the master value for an integrated network, SetValue = [1] must be configured in the Master values output systembus parameter.
0x5020:001
If Application feedback (B) = [3] is configured in the Master values output systembus parameter, a setpoint step-change will occur in the event of an encoder error.
0x5020:001
Load encoder/master encoder error response = [2] warning
Clutch is switched to the virtual master.
-
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2C55
Load encoder/master encoder error response
Selection of the response to the triggering of the encoder signal loss monitoring.
Only active when used as:
–
Feedback system for motor control if set,
 
–
Signal source for the "position counter" function.
 
Associated event ID:
–
537490180 | 0x20097304 - Error - Load encoder/master encoder
 
0
No response
1
Fault > CiA402
2
Warning
0x500B:010
Actual position
–
Read only
 
The current position value is resolved with 4 decimal positions.
0x5042:016
Set position of selected master value
–
Read only