Positioning to torque limit

Positioning at the torque limit makes it possible to perform positioning against an obstacle. This is e.g. necessary for pressing materials. When this function is activated, the assigned control bit has the level high, and the following error is constantly ignored during positioning. When the function is deactivated, the following error is deleted. The function is activated via a selectable bit in the control signal.
The following signals are available for activating the function:
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5030:009
Activate "Positive stop positioning"
Positioning against an obstacle.
The following error is permanently ignored during the positioning process.
0
FALSE
Positioning is deactivated.
1
TRUE
The positioning function is always activated.
124
Status bit 24 (reserved)
The positioning function is activated via the corresponding control bit.
125
Status bit 25 (reserved)
126
Status bit 26 (reserved)
127
Status bit 27 (reserved)