Disconnect position follower from cam disc
When thexSyncIn input changes from TRUE to FALSE, the axis is brought to a standstill.
The deceleration mode for the deceleration process is specified in the scPar structure using the eSyncOutMode parameter.
|
Clutch mode eSyncOutMode |
Description |
|---|---|
|
0 (Stop) |
The slave axis is decelerated to a standstill via a ramp generator according to the parameters of the stop. |
|
1 (MoveToParkPos) |
The slave axis is decoupled to the park position via the profile generator using the parameters scPar.lrSyncDec and scPar.lrSyncJerk. |
Disengage into the park position
The axis is brought to a standstill using the parameters lrSyncVel, lrSyncAcc, lrSyncDec, and lrSyncJerk.
The parameter lrParkPosition determines the position at which the axis should come to a standstill.
The movement is independent of the movement of the reference value.
Parameters to be set
The parameters to be set are located in the scPar structure.
|
Param Data |
Description |
|---|---|
|
eSyncOutMode L_TS2P_SyncInMode |
Initial value: MoveToParkPos |
|
lrSyncInVel LREAL |
Initial value: 100
|
|
lrSyncInAcc LREAL |
Initial value: 1000
|
|
lrSyncInDec LREAL |
Initial value: 1,000
|
|
lrSyncInJerk LREAL |
Initial value: 1000000
|
|
lrParkPosition LREAL |
Initial value: 0
|
Decoupling to a standstill
The axis is brought to a standstill using the stop parameters.
No defined position is approached.
This clutch mode is independent of the movement of the master axis.
Parameters to be set
The parameters to be set are located in the scPar structure.
|
Parameter Data type |
Description |
|---|---|
|
eSyncOutMode L_TS2P_SyncInMode |
Initial value: MoveToParkPos |