Disconnect position follower from cam disc

When thexSyncIn input changes from TRUE to FALSE, the axis is brought to a standstill.

The deceleration mode for the deceleration process is specified in the scPar structure using the eSyncOutMode parameter.

Clutch mode

eSyncOutMode

Description

0 (Stop)

The slave axis is decelerated to a standstill via a ramp generator according to the parameters of the stop.

1 (MoveToParkPos)

The slave axis is decoupled to the park position via the profile generator using the parameters scPar.lrSyncDec and scPar.lrSyncJerk.

Disengage into the park position

The axis is brought to a standstill using the parameters lrSyncVel, lrSyncAcc, lrSyncDec, and lrSyncJerk.

The parameter lrParkPosition determines the position at which the axis should come to a standstill.

The movement is independent of the movement of the reference value.

Parameters to be set

The parameters to be set are located in the scPar structure.

Param

Data

Description

eSyncOutMode

L_TS2P_SyncInMode

Initial value: MoveToParkPos

lrSyncInVel

LREAL

Initial value: 100

 

lrSyncInAcc

LREAL

Initial value: 1000

 

lrSyncInDec

LREAL

Initial value: 1,000

 

lrSyncInJerk

LREAL

Initial value: 1000000

 

lrParkPosition

LREAL

Initial value: 0

 

Decoupling to a standstill

The axis is brought to a standstill using the stop parameters.

No defined position is approached.

This clutch mode is independent of the movement of the master axis.

Parameters to be set

The parameters to be set are located in the scPar structure.

Parameter

Data type

Description

eSyncOutMode

L_TS2P_SyncInMode

Initial value: MoveToParkPos