Inputs

Basic functions

(missing or bad snippet)

Technology functions

Identifier

Data type

Description

Axis

AXIS_REF

Reference to the axis

MasterValues

L_MC1P_IAXIS_REF_MASTERVALUES

Connection for the reference values (reference axis, master axis)

scPar

L_TS2P_scPar_FlexCamHigh

The parameter structure contains the parameters of the technology module.

scAccessPoints

L_TS2P_scAP_FlexCamHigh

Structure of the attack points

The attack points can be used to influence the signal flow or functions of the technology module.

xClutchClose

BOOL

Clutch in front of the cam disc in the conductance path is synchronized to the conductance

  • Initial value: FALSE

This function is permanently active and does not cause a state change in the TM

TRUE

Input position of the cam disc is coupled to the reference position

FALSE

Decouple the input position of the cam disc to the decoupling position

xLoadClutchPos

BOOL

Preload function of the guide value clutch

  • Initial value: FALSE

This function is available at any time and can cause a position jump when used if the TM is in the Camming or ACC_DEC_SYNC state.

TRUE

The initial position of the clutch is loaded to the value of lrLoadClutchPos as long as the input xLoadClutchPos is set.

FALSE

The output position of the clutch is generated by the clutch.

lrLoadClutchPos

BOOL

Load position for the xLoadClutchPos function

 

xFindClutchXPos

BOOL

 

 

Identification function for automatic preloading of the conductance coupling

  • Initial value: FALSE

This function can be used to find the appropriate X position of the cam disc for the current axis position. This is necessary in order to then be able to switch to CAMMING mode with xSyncIn without movement

TRUE

The TM switches to the IDENTIFICATION state and determines the X position of the cam disc corresponding to the current target position of the axis. This position is preloaded at the output of the coupling.

FALSE

The output position of the coupling is generated by the coupling.

xSyncIn

BOOL

Synchronize slave axis to the resulting position from the cam disc.

The input is level-controlled and evaluates a high level.

  • Parameter: Coupling mode eSyncMode

  • Initial value: FALSE

TRUE

Engage the cam disc.

FALSE

Disengage from the cam disc

xSyncPosRestore

BOOL

 

Remove coupling offset

The offset is caused by relative engagement (scPar.eSyncInMode = 1/ProfGenRelative)

FALSEäTRUE

An existing coupling offset is reduced to 0 using the parameters scPar.lrSyncVel, scPar.lrSyncDec, and lrSyncJerk.

xCamChangeInstant

BOOL

The input is edge-triggered and evaluates the rising edge.

FALSE äTRUE

Switch from the cam disc currently in use to the newly created cam disc during the current cycle.

lrSetOffsetPosX

LREAL

Position offset of the master axis

The resulting x-position of the cam disc is calculated by adding the master axis position to the offset specified by this input.

lrSetOffsetPosY

LREAL

Position offset of the slave axis

The resulting position of the slave axis is calculated by adding the y-position to the offset specified by this input.

lrSetScalingX

LREAL

Scaling factor of the master axis

The resulting x-position of the cam disc is calculated by multiplying the master axis position by the scaling factor specified by this input.

lrSetScalingY

LREAL

Scaling factor of the slave axis

The resulting stretched/compressed y target position is calculated by multiplying the y value of the cam disc by the scaling factor specified in this input.

CamTable1

MC_CAM_REF

Reference to cam disc 1

CamTable2

MC_CAM_REF

Reference to cam disc 2

CamTable3

MC_CAM_REF

Reference to cam disc 3

CamTable4

MC_CAM_REF

Reference to cam disc 4

wSetCamTable

WORD

Selection of a cam disc

1

Cam disc 1

2

Cam disc 2

3

Cam disc 3

4

Cam disc 4

xCamSequencer

BOOL

TRUE

Activate switching sequence for cam discs.

Cam discs are driven according to the switching sequence in parameter eCamSequenceMode .