L_TS2P_scPar_FlexCamHigh

Basic functions

(missing or bad snippet)

Technology functions

Designator

Data type

Description

eClutchMode

L_TS2P_SyncMode

Mode for the engagement/disengagement process

  • Initial value: 2 (absolute distance-based)

2

" DistAbsolute ": Profile-based engagement

10

"Instant absolute": Immediate coupling; the slave position is set to the y position.

lrClutchInDistX

LREAL

Distance of the engagement movement of the lead value clutch in distance-based clutch mode

  • Unit: MasterAxis

  • Initial value: 90

lrClutchOutDistX

LREAL

The master target position in distance-based clutch mode from which the clutch is fully closed.

  • Unit: units MasterAxis

  • Initial value: 90

lrClutchOutPosX

LREAL

Target disengagement position of the conductance clutch in path-based clutch mode

The clutch is stopped at this position as soon as the disengagement process is complete.

  • Unit: units MasterAxis

  • Initial value: 0

eAllowedDirection

L_TB2P_AllowedDirection

Direction of travel for the Clutch function

If eAllowedDirection= 1 or 2, the synchronization process is started in the parameterized direction. If the cam disc is stationary, movement of the drive in the prohibited direction is thus prevented.

  • Initial value: 0 (Both)

0

Positive and negative direction of rotation

The slave axis may engage in both directions.

1

Positive direction of rotation only

The slave axis may only engage in the positive direction.

2

Only negative direction of rotation

The slave axis may only engage in the negative direction.

xLimitAllowedDirection

BOOL

 

Activate total setpoint restriction to the permitted range (eAllowedDirection).

TRUE

The speed of the total setpoint is limited to the permitted range (eAllowedDirection).

For example, a negative total setpoint speed is not possible if eAllowedDirection = 1 (positive direction of rotation only).

FALSE

The speed of the total setpoint can be in a non-permitted range if the control value speed is negative.

lrToleranceAllowedDirection

LREAL

Maximum setpoint position in the blocked direction of rotation (eAllowedDirection) before an error is triggered.

This tolerance window is only active if xLimitAllowedDirection = TRUE.

  • Unit: unit

  • Initial value: 5

xCamCyclic

BOOL

Driving mode of the cam

TRUE

The cam is executed cyclically.

FALSE

The cam is executed once.

xMasterAbsolute

BOOL

Reference to the position of the master axis

  • Initial value: TRUE

TRUE

Absolute reference between the position of the master axis and the cam

FALSE

Relative reference between the position of the master axis and the cam

xSlaveAbsolute

BOOL

Reference to the position of the slave axis

  • Initial value: TRUE

TRUE

Absolute reference between the position of the slave axis and the cam

FALSE

Relative reference between the position of the slave axis and the cam (initial value)

eOffsetModeX

L_TS2P_OffsetMode

Mode for accepting the offset for the master axis ( lrSetOffsetPosX input)

0

x_zero: Acceptance of the offset in the "zero crossing" of the cam

1

Instant absolute: Immediate acceptance of the offset

2

Profile generator absolute: Acceptance of the offset via the ramp generator with the parameters

  • lrSetOffsetScalingXVel

  • lrSetOffsetScalingXAcc

  • lrSetOffsetScalingXDec

  • lrSetOffsetScalingXJerk

eOffsetModeY

L_TS2P_OffsetMode

Mode for accepting the offset for the slave axis (lrSetOffsetPosY input)

0

x_zero: Acceptance of the offset in the "zero crossing" of the cam

1

Instant absolute: Immediate acceptance of the offset

2

Profile generator absolute: Acceptance of the offset via the ramp generator with the parameters

  • lrSetOffsetScalingYVel

  • lrSetOffsetScalingYAcc

  • lrSetOffsetScalingYDec

  • lrSetOffsetScalingYJerk

lrSetOffsetScalingXVel

LREAL

Limitation of the speed for compensating an offset and scaling change

  • Scaling the position via the ramp generator Unit: Units/s

  • Initial value: 100

lrSetOffsetScalingXAcc

LREAL

Limitation of the acceleration for compensating an offset and scaling change

  • Scaling the position via the ramp generator Unit: Units/s 2

  • Initial value: 1000

lrSetOffsetScalingXDec

LREAL

Limitation of the deceleration for compensating an offset and scaling change

  • Scaling the position via the ramp generator Unit: Units/s 2

  • Initial value: 1000

lrSetOffsetScalingXJerk

LREAL

Specification of the jerk for compensating an offset and scaling change between the master and x axis

  • Scaling the position via the ramp generator Unit: units/s 3

  • Initial value: 1000000

eScalingModeX

L_TS2P_ScalingMode

Mode for accepting the scaling factor for the master axis ( lrSetOffsetPosX input)

0

x_zero: Scaling in "zero crossing" of the cam

1

Instant absolute: Absolute scaling of the position

2

Instant relative: Relative scaling of the position, absolute scaling of the speed

3

Profile generator absolute: Absolute scaling of the position via the ramp generator with the parameters

  • lrSetOffsetScalingXVel

  • lrSetOffsetScalingXAcc

  • lrSetOffsetScalingXDec

  • lrSetOffsetScalingXJerk

4

Profile generator relative:

Relative scaling of the position via the ramp generator with the parameters

  • lrSetOffsetScalingXVel

  • lrSetOffsetScalingXAcc

  • lrSetOffsetScalingXDec

  • lrSetOffsetScalingXJerk

eScalingModeY

L_TS2P_ScalingMode

Mode for accepting the scaling factor for the slave axis ( lrSetOffsetPosY input)

0

x_zero: Scaling in "zero crossing" of the cam

1

Instant absolute: Absolute scaling of the position

2

Instant relative: Relative scaling of the position, absolute scaling of the speed

3

Profile generator absolute: Absolute scaling of the position via the ramp generator with the parameters

  • lrSetOffsetScalingYVel

  • lrSetOffsetScalingYAcc

  • lrSetOffsetScalingYDec

  • lrSetOffsetScalingYJerk

4

Profile generator relative: Relative scaling of the position via the ramp generator with the parameters

  • lrSetOffsetScalingYVel

  • lrSetOffsetScalingYAcc

  • lrSetOffsetScalingYDec

  • lrSetOffsetScalingYJerk

lrSetOffsetScalingYVel

LREAL

Limitation of the speed for compensating an offset and scaling change

lrSetOffsetScalingYAcc

LREAL

Limitation of the acceleration for compensating an offset and scaling change

  • Unit: Units/s 2

  • Initial value: 1000

lrSetOffsetScalingYDec

LREAL

Limitation of the deceleration for compensating an offset and scaling change

  • Unit: Units/s 2

  • Initial value: 1000

lrSetOffsetScalingYJerk

LREAL

Specification of the jerk for compensating an offset and scaling change between the slave and y axis

  • Unit: units/s 3

  • Initial value: 1000000

xCalcCamBounds

BOOL

TRUE

Extreme values of the slave axis (MP_ lrSlaveMaxPos , MP_ lrSlaveMinPos , MP_ lrSlaveMaxVel , MP_ lrSlaveMaxAcc ) are calculated depending on the parameters lrMasterMaxVel and lrMasterMaxAcc .

lrMasterMaxVel

LREAL

Maximum speed of the master axis for checking the cams

  • Unit: unit/s

  • Initial value: 100

lrMasterMaxAcc

LREAL

Maximum acceleration of the master axis for checking the cams

  • Unit: Units/s 2

  • Initial value: 1000

eCamSequenceMode

L_TS2P_CamSequenceMode

Switching sequence of the cams

The switching sequence is enabled via the xCamSequencer input.

0

xCamSequencer = TRUE: Execute cam 1 cyclically

1

xCamSequencer = TRUE: Execute cam 3 cyclically

2

xCamSequencer = TRUE:

  • Execute cam 1 once, then

  • Execute cam 3 cyclically

xCamSequencer = TRUE æ FALSE:

  • Execute cam 3 once, then

  • Execute cam 1 once

3

xCamSequencer = TRUE:

  • Execute cam 1 once,

  • Execute cam 2 once, then

  • Execute cam 3 cyclically

xCamSequencer = TRUE æ FALSE:

  • Execute cam 3 once,

  • Execute cam 4 once, then

  • Execute cam 1 once

eSyncInMode

L_TS2P_SyncInMode

 

 

Mode for the positioning function of the position follower on the output of the cam disc

Note: The permitted direction of rotation for the xSyncIn function can be selected using the scPar.eSyncDirection parameter. The following settings are supported: mcPositiveDirection, mcNegativeDirection, and mcShortestWay

  • Initial value: 0 ProfGenAbsolute

 

0

ProfGenAbsolute: The axis is positioned to the position of the cam disc, taking into account scPar.eSyncDirection, scPar.lrSyncAcc, lrSyncDec, lrSyncJerk

1

ProfGenRelative: The axis is positioned at the speed of the cam disc, taking into account scPar.eSyncDirection, scPar.lrSyncAcc, lrSyncDec, and lrSyncJerk. Any resulting offset is displayed under lrOffsetSyncPos.

eSyncOutMode

L_TS2P_CamStopMode

Mode for desynchronizing from the cam disc.

 

0

Stop: The axis is brought to a standstill, taking into account the HALT delay.

1

MoveToParkPos: The axis is brought to the parking position scPar.lrParkposition, taking into account lrSyncDec and lrSyncJerk.

eSyncDirection

L_TS2P_SyncDirection

Direction specification for the "SyncIn" function

1

PositiveDirection

2

NegativeDirection

3

ShortestWay

lrSyncVel

LREAL

Maximum speed at which the SyncIn process should be performed.

  • Unit: units/s SlaveAxis

  • Initial value: 100

lrSyncAcc

LREAL

Acceleration for the SyncIn process.

  • Unit: units/s2 SlaveAxis

  • Initial value: 100

lrSyncDec

LREAL

Deceleration for the SyncIn process.

  • Unit: units/s2 SlaveAxis

  • Initial value: 100

lrSyncJerk

LREAL

Jerk for the SyncIn process.

  • Unit: units/s3 SlaveAxis

  • Initial value: 1,000,000

lrParkPosition

LREAL

Position to which the drive is positioned when XSyncIn = FALSE and scPar.eSyncOutMode = MoveToParkPos.

  • Unit: unit SlaveAxis

  • Initial value: 100