Error management and Quickstop

During a quick stop, the axis for which no quick stop was requested follows the in subindex 35 parameterized coupling mode. This means that during a quick stop in the secondary axis, the main axis temporarily follows the secondary axis.

There are three possible fault scenarios for the single-axis kinematic.

  • Error in the single-axis kinematic (e.g. due to skewness between the individual axes)

  • Error in the main axis

  • Error in the following axis

In each of these three scenarios, the single-axis kinematic immediately switches to the ErrorStop state.

The behavior in the possible error scenarios is described below.

Error in the single-axis kinematic

  • An error is also triggered in the main axis

  • An error is also triggered in the following axis

  • The main and following axes execute their own error response.

Error in the main axis

  • An error is also triggered in the single-axis kinematic

  • An error is also triggered in the following axis

  • The main and following axes execute their own error response.

Error in the following axis

  • An error is also triggered in the single-axis kinematic

  • An error is also triggered in the main axis

  • The main and following axes execute their own error response.