states of kinematic and motion-axis

Based on the states of the single axis, the states described below can be derived for the single-axis kinematics.

  • The single-axis kinematic is always in one of these states.

  • The arrows between the states mark possible state changes. The dashed arrows mark error-dependent state changes.

Status diagram

2

Disabled: one of the axes is not linked / kinematic deactivated

3

Standby: Axes are linked, controllers are disabled.

  • Main axis status: Disabled

  • State of following axis: Disabled

4

WaitForSyncIn: In the coupling mode"Absolute position" and activated manual alignment, the system waits in this state until the alignment has been activated manually.

  • Main axis status: Disabled

  • State of secondary axis: Disabled

5

SyncIn: In coupling mode "Absolute position" (Sub 35 = 0), the axes will be aligned in this state.

  • Main axis status: Disabled

  • State of secondary axis: DiscMotion

6

Synchronized: Axes are linked, controllers are enabled.

Incoupling mode "Absolute position" (Sub 35 = 0):

  • If the reference position is known: Axes are aligned. Coupled movements can be started.

  • If the reference position is unknown: Only homing can be started from this state.

With coupling mode <> "Position Absolute" (Sub 35 <> 0):

  • Coupled movements can be commanded.

  • Main axis status: current single axis status

  • Secondary axis status: SyncMotion

8

Homing: Axes are linked, one axis is in the Homing state

  • Main axis status: Homing

  • Secondary axis status: Homing

11

Service: Axes are linked but temporarily decoupled via FB L_MK1P_GantryManualControl. Individual movement of an axis is possible

  • Main axis status: current single axis status

  • Auxiliary axis status: Current single axis status

1

ErrorStop: at least one axis is in the ErrorStop state

  • Main axis status: ErrorStop

  • Auxiliary axis status: ErrorStop

Transition number

Description

[3]

  • Main and secondary axes are linked

  • Kinematics is activated

  • Controller is disabled

[2]

  • One of the axes is not linked or the kinematic is deactivated

[4]

  • "Absolute position" coupling mode is activated (subindex 35 = 0)

  • The controller is enabling

  • The reference position of the axes are known

  • Manual alignment is to take place (subindex 50 = 0)

[5]

  • "Absolute position" coupling mode is activated (subindex 35 = 0)

  • The controllers are enabled

  • the reference position of the axes are known

  • Manual alignment has been activated via the FB L_MK1P_GantryManualControl (xExecuteSyncIn = TRUE)

[6]

  • "Absolute position" coupling mode is activated (subindex 35 = 0)

  • The controllers are enabled

  • The reference position of the axes are known

  • Alignment (manual (sub 50 = 0) or automatic (sub 50 = 1)) has been completed

[7]

  • The reference search for both axes has been successfully completed.

[8]

  • The reference search was started via an FB.

[9]

  • The coupling mode is <> "Position Absolute" (subindex 35 <> 0) and the controller is enabling

[10]

  • "Absolute position" coupling mode is activated (subindex 35 = 0)

  • the controller is enabling

  • the reference position of the axes are known

  • Automatic alignment is to take place ((Sub 50 = 1))

[11]

  • The "Service mode" was activated via the FB L_MK1P_GantryManualControl (xEnableServiceMode =True)

The current status is displayed in the parameter Single-axis kinematics: Status (subindex 33).

The status of the two coupled axes is "coupled" by the kinematics.