L_TP2P_scSF_TemperatureControlBase

Structure of the signal flow

The contents of the L_TP2P_scSF_TemperatureControlBase structure are read-only and offer a practical diagnostics option within the signal flow ( Signal flow diagrams ).

Name

Data type

Description

IP01_lrSetTemp

LREAL

Temperature setpoint for the "temperature control" operating mode (eModeTempCtrl parameter = REGULATION)

  • Unit: °C or °F

MP01_lrTempSetFiltered

LREAL

Filtered temperature setpoint

  • Unit: °C or °F

MP02_lrTempActUnfiltered

LREAL

Unfiltered actual temperature value

  • Unit: °C or °F

MP03_lrTempCtrlDifference

LREAL

System deviation between temperature setpoint and actual value

  • Unit: °C or °F

MP04_lrTempCtrlPropValue

LREAL

Process value of the proportional component (P) of the controller

MP05_lrTempSetFilterTime

LREAL

PT1 filter time constant for the temperature setpoint

With the value '0', filtering is deactivated.

  • Unit: s

MP06_lrTempActFilterTime

LREAL

PT1 filter time constant for the actual temperature value

With the value '0', filtering is deactivated.

  • Unit: s

Example:

A task cycle time of 10 ms and the common factor of 500 result in a filter time constant of 5 seconds.

MP07_lrTempCtrlGain

LREAL

P parameter of the PID controller

  • Unit: %/°C / %/°F

MP08_lrTempCtrlResetTime

LREAL

Reset time (I parameter) of the PID controller

  • Unit: s

MP09_lrTempCtrlRateTime

LREAL

Rate time (D parameter) of the PID controller

  • Unit: s

MP10_lrTempCtrlIntergral
Value

LREAL

Process value of the integral-action component (I) of the controller

MP11_lrTempCtrlDerivative
Value

LREAL

Process value of the differential component (D) of the controller

MP12_lrTempCtrlOutPct

LREAL

Correcting variable of the controller

  • Unit: %

MP13_lrIdentS1ElapsedTime

MP14_lrIdentS1TempActGradient

MP15_lrIdentS2TempStart

MP16_lrIdentS2ElapsedTime

MP17_lrIdentS2TempActGradient

MP18_lrIdentS3TauDeadAct

MP19_lrIdentS3TauDeadMax

LREAL

see description in section
Procedure after activating the parameter identification

OP01_lrActTemp

LREAL

Actual temperature value

  • Unit: °C or °F

MP_xInternalControlActive

BOOL

The technology module is currently controlled by the InternalControl functionality (visualization template). Commands from the tm interface are ignored.