Changing the traversing step during operation (traversing step override)

Function

The override function for the traversing step allows a change of the traversing step (input lrPitchOverride) during the running traversing operation. For the traversing step, the override causes a proportional influence on the traversing speed.

Input lrPitchOverride = 1 (100 %)

Input lrPitchOverride < 1

Depending on the selected override mode (parameter eOverrideMode), the traversing step override is included in the run-up/run-down ramp.

Override mode "OverrideAccDec"

The run-up/down angle, like the traversing step, is evaluated with the traversing step override.

Override mode "OverrideAccDec

Override mode "OverrideConstant"

The run-up/down angle remains constant regardless of the traversing step override.

Override mode "OverrideConstant

Function-relevant parameters

The parameter for selecting the override mode is in the structure L_TW2P_scPar_Traverser .

  • eOverrideMode, L_TW2P_eTraverser_OverrideMode, Initial value: 1 (OverrideConstant)