Diameter calculation

The exact diameter value is required for the conical coil operating mode.

The source for the diameter value is defined via the eDiameterMode parameter:

Identifier

Data type

Description

eDiameterMode

L_TW2P_TraverserDiamMode

 

 

Source for the winding diameter

  • Initial value: 0 (DiamInput)

0

DiamInput:

The value at input lrSetDiam is used as the current winding diameter.

1

DiamCalc:

The winding diameter is calculated using the number of layers and material thickness (parameter lrMaterialThickness).

2

DiamInputScaled:

The winding diameter at the lrSetDiam input is used as a scaled variable 0 to 1.

Execution

The diameter calculation is activated with the setting eDiameterMode = 1 and lrMaterialThickness > 0

In this case, the layer counter is taken and multiplied by the material thickness. The layer counter is always active.

The lower limit of the calculated diameter is set by the parameter lrMinDiam. For large diameter values there is no upper limit in the technology module.