UIDesigner.TargetDeviceManager.Authorization
In order to configure the rights for authorization, the »PLC Designer« must be connected to the controller and the user management must be activated (Controller.UserManagement).
After activation, the user can open the device window and select the "Users and Groups" tab. The Group EasyUi already exists here. All users in this group can access the controller via the "EASY UI Designer." Selecting the "Access Rights" tab shows the configurable objects. The object "Runtime Object\Device\Remote Connections\EasyUi Interface" is intended for allocating the relevant rights.
|
PLC Designer right for object EasyUiInterface |
EASY UI Designer right for Server Manager UI |
Description of authorization |
|---|---|---|
|
View |
View |
View rights are needed to connect the Target Device Manager to the controller with read-only rights. |
|
Execute |
Execute |
Execute rights are needed to deploy the Client Project to the controller via the Target Device Manager. |
|
Modify |
Change |
Modify rights are needed to deploy the Server Project to the controller via the Target Device Manager. |
|
Add / Remove |
Admin |
Is not used. |