Information on the network

The following parameters show information on the network.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2362:004
Active EtherCAT settings: Device ID
–
Read only
 
Display of the clear device address in the network which is defined via rotary encoder switch or object 0x2361:004.
0x2362:006
Active EtherCAT settings: Station address
–
Read only
 
Display of the active station address.
0x2362:007
Active EtherCAT settings: Tx length
–
Read only
 
Display of the length of the transmitted cyclic data in bytes.
0x2362:008
Active EtherCAT settings: Rx length
–
Read only
 
Display of the length of the received cyclic data in bytes.
0x2367:001
EtherCAT service status: Download parameter file
–
Read only
 
0x2368
EtherCAT status
–
Read only
 
Display of the current network status.
1
Initialization
Network initialization is active.
–
No PDO/SDO transmission.
 
–
Device identification is possible by network scan.
 
2
Pre-Operational
The network is active.
–
SDO transmission (CoE communication via mailbox) is possible.
 
–
No PDO transmission.
 
3
Bootstrap
Firmware update active.
–
For the firmware update, the FoE protocol is used.
 
–
No PDO transmission.
 
4
Safe-Operational
–
SDO transmission (CoE communication via mailbox) is possible.
 
–
PDO transmission:
 
–
The input data in the process image are updated.
 
–
The output data from the process image are not transmitted.
 
 
8
Operational
Normal operation
–
PDO/SDO transmission is possible.
 
–
Network synchronisation is successful (if used).
 
0x2369
EtherCAT error
–
Read only
 
Bit coded display of EtherCAT errors.
Bit 0
Watchdog elapsed
Bit 2
Invalid configuration
Bit 3
Stack init error
Bit 4
Invalid process data