0x2859:001
|
Network monitoring: Watchdog elapsed
|
Selection of the response to a permanent interruption of the communication to the IO controller.
Associated event ID:
–
33168 | 0x8190 - Network - Watchdog time-out
|
|
0
|
No response
|
|
|
11
|
Information
|
|
12
|
Warning
|
|
16
|
Trouble
|
|
23
|
Fault > inverter disabled
|
|
0x2859:003
|
Network monitoring: Invalid configuration
|
Selection of the response triggered by the reception of invalid configuration data.
Associated event ID:
–
33414 | 0x8286 - Network - PDO mapping error
|
|
0
|
No response
|
|
|
11
|
Information
|
|
12
|
Warning
|
|
16
|
Trouble
|
|
23
|
Fault > inverter disabled
|
|
0x2859:004
|
Network monitoring: Initialisation error
|
Selection of the response triggered by the occurrence of an error during the initialization of the network component.
Associated event ID:
–
33170 | 0x8192 - Network - Initialization error
|
|
0
|
No response
|
|
|
11
|
Information
|
|
12
|
Warning
|
|
16
|
Trouble
|
|
23
|
Fault > inverter disabled
|
|
0x2859:005
|
Network monitoring: Invalid process data
|
Selection of the response triggered by the reception of invalid process data.
Process data marked as invalid (IOPS is "BAD") are received by the IO Controller. Typically in case of
–
a PLC in STOP state,
–
alarms,
–
acyclic demand data.
Associated event ID:
–
33171 | 0x8193 - Network - Invalid cyclic process data
|
|
0
|
No response
|
|
|
11
|
Information
|
|
12
|
Warning
|
|
16
|
Trouble
|
|
23
|
Fault > inverter disabled
|