Service life diagnostics
The following parameters provide some information about the use of the inverter.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2D81:001
|
Life-diagnosis: Operating time
–
Read only: x s
|
Display showing for how long the device has been running so far (device status “operation enabled”).
|
|
|
0x2D81:002
|
Life-diagnosis: Power-on time
–
Read only: x s
|
Display showing for how long the device has been supplied with line voltage so far.
|
|
|
0x2D81:003
|
Life-diagnosis: Control unit operating time
–
Read only: x ns
|
Display showing for how long the control unit has been supplied with voltage so far. This includes the external 24-V supply and voltage supply via USB module.
|
|
|
0x2D81:004
|
Life-diagnosis: Main switching cycles
–
Read only
|
Display of the number of switching cycles of the mains voltage.
|
|
|
0x2D81:006
|
Life-diagnosis: Short-circuit counter
–
Read only
|
Display of the number of short circuits that have occurred.
|
|
|
0x2D81:007
|
Life-diagnosis: Earth fault counter
–
Read only
|
Display of the number of earth faults that have occurred.
|
|
|
0x2D81:008
|
Life-diagnosis: Clamp active
–
Read only
|
Display of the number of "Clamp responded too often" errors that have occurred.
–
"Clamp" = short-time inhibit of the inverter in V/f operation when the current limit shown in 0x2DDF:002 is reached.
|
|
|
0x2D81:009
|
Life-diagnosis: Fan operating time
–
Read only: x s
|
Display showing for how long the internal fan has been running so far.
|
|