Diagnostic parameters
The inverter provides many diagnostic parameters which are helpful for operation, maintenance, error diagnosis, error correction, etc.
–
The following overview lists the most common diagnostic parameters.
–
Further parameters for more specific diagnostic purposes are described in the following subchapters.
–
The diagnostic parameters can only be read and cannot be written to.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2012:015
|
Device information: Supported functions
–
Read only
|
||
|
0x2030
|
CRC parameter set
–
Read only
|
Display of the 32-bit hash sum for the integrity check of the parameter set.
|
|
|
0x2B0B
|
Ramp generator frequency
–
Read only: x.x Hz
|
Display of the current frequency setpoint. The frequency setpoint is internally transferred to the motor control (based on scaling and ramp generator).
The frequency setpoint is internally transferred to the motor control (based on scaling and ramp generator).
|
|
|
0x2B0E
|
Frequency setpoint
–
Read only: x.x Hz
|
Display of the frequency setpoint currently assigned.
–
Depending on the present operating conditions, this value may differ from the current output frequency 0x2DDD.
|
|
|
0x2B0F
|
Output frequency motor
–
Read only: x.x Hz
|
||
|
0x2D4F
|
Motor utilisation (i²xt)
–
Read only: x %
|
Display of the current thermal motor utilisation.
|
|
|
0x2D87
|
DC-bus voltage
–
Read only: x V
|
Display of the current DC-bus voltage.
|
|
|
0x2D88
|
Motor current
–
Read only: x.x A
|
Display des present current-r.m.s. value.
|
|
|
0x2D89
|
Motor voltage
–
Read only: x VAC
|
Display of the current motor voltage.
|
|
|
0x2DA2:001
|
Output power: Effective power
–
Read only: x.xxx kW
|
Display of the active output power for an energy analysis in the respective application.
|
|
|
0x2DA2:002
|
Output power: Apparent power
–
Read only: x.xxx kVA
|
Display of the apparent output power for an energy analysis in the respective application.
|
|
|
0x2DA3:001
|
Output energy: Motor
–
Read only: x.xx kWh
|
Display of the output power in motor mode for an energy analysis in the respective application.
|
|
|
0x2DA3:002
|
Output energy: Generator
–
Read only: x.xx kWh
|
Display of the output power in generator mode for an energy analysis in the respective application.
|
|
|
0x2DD1:001
|
Motor currents: Actual D-current (id)
–
Read only: x.xx A
|
Display of the actual D current.
|
|
|
0x2DD1:002
|
Motor currents: Actual Q-current (iq)
–
Read only: x.xx A
|
Display of the actual Q current.
|
|
|
0x2DD1:003
|
Motor currents: Setpoint D-current (id)
–
Read only: x.xx A
|
Display of the setpoint D current.
|
|
|
0x2DD1:004
|
Motor currents: Setpoint Q-current (iq)
–
Read only: x.xx A
|
Display of the setpoint Q current.
|
|
|
0x2DD1:005
|
Motor currents: Motor current (Ieff)
–
Read only: x.xx A
|
Display of the effective motor current.
|
|
|
0x2DD3:001
|
Speed setpoints: Speed setpoint
–
Read only: x rpm
|
Display of the speed setpoint value 1.
|
|
|
0x2DD3:003
|
Speed setpoints: Speed setpoint limited
–
Read only: x rpm
|
Display of the limited speed setpoint.
|
|
|
0x2DD4:001
|
Speed controller output signals: Output signal 1
–
Read only: x.x %
|
Display of the output signal 1 from the speed controller.
|
|
|
0x2DD4:002
|
Speed controller output signals: Output signal 2
–
Read only: x.x %
|
Display of the output signal 2 from the speed controller.
|
|
|
0x2DDC
|
Actual slip value
–
Read only: x.x Hz
|
Display of the actual slip.
|
|
|
0x2DDD
|
Output frequency
–
Read only: x.x Hz
|
Display of the current output frequency of the inverter.
|
|
|
0x2DDF:001
|
Axis information: Rated current
–
Read only: x.xx A
|
Display of the rated current of the axis.
|
|
|
0x2DDF:002
|
Axis information: Maximum current
–
Read only: x.xx A
|
Display of the maximum current of the axis.
|
|
|
0x6077
|
Actual torque
–
Read only: x.x %
|
Display of the actual torque.
|
|
|
0x6078
|
Actual current
–
Read only: x.x %
|
Display of the motor actual current.
|
|
|
0x6079
|
DC-bus voltage
–
Read only: x.xxx V
|
Display of the current DC-bus voltage.
|
|