Status LEDs
The LEDs "BUS RDY" and "BUS ERR" indicate the connection status to the IO-Controller.
|
"BUS RDY" LED (green)
|
State
|
Meaning
|
|
Off
|
Not connected
|
No connection to the IO-Controller
|
|
Blinking (1 Hz)
|
Connected
|
IO-Controller in STOP
|
|
On
|
Data exchange
|
IO-Controller in RUN (DATA_EXCHANGE)
|
|
"BUS ERR" LED (red)
|
State
|
Meaning
|
|
Off
|
No fault
|
No fault
|
|
Blinking (1 Hz)
|
IO-Device identifies (localises)
|
The PROFINET function "node flashing test" is triggered by IO-Controller. The flickering LED serves to identify (locate) an accessible IO-Device.
|
|
Blinking fast
|
Impermissible settings
|
Impermissible settings: Stack, station name or IP parameters are invalid.
|
|
On
|
Fault
|
Communication error (e. g. Ethernet cable removed)
|
The "L/A" LEDs indicate the connection status of ports X396 and X397.
|
LED "L/A"
|
Status
|
Meaning
|
|
off
|
Not connected
|
Network not available
|
|
on
|
Connected
|
Network available
No data transfer
|
|
blinking
|
Traffic
|
Data transfer
|