Motor control mode

The inverter supports different modes for closed-loop/open-loop motor control.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2C00
Motor control mode
–
Setting can only be changed if the inverter is disabled.
 
Selection of the motor control mode.
2
Servo control (SC ASM)
This control mode is used for servo control of an asynchronous motor.
A motor encoder must be connected to the inverter. This motor encoder is used as a feedback system for the motor control.
4
Sensorless vector control (SLVC)
This control type is used for sensorless vector control of an asynchronous motor.
6
V/f characteristic control (VFC open loop)
This control mode is used for the speed control of an asynchronous motor via a V/f characteristic and is the simplest control mode.
7
V/f characteristic control (VFC closed loop)
The control mode is used for speed control of an asynchronous motor via a V/f characteristic with speed feedback.
A motor encoder must be connected to the inverter. This motor encoder is used as a feedback system for the motor control.
8
Sensorless control for synchronous motors (SLSM-PSM)
This control type is used for the sensorless control of a synchronous motor.
–
Only available up to 15 kW with 3 x 230/240 V and up to 30 kW with 3 x 400/480 V.
 
 
The detailed description of each motor control type can be found in the chapter "Configuring the motor control".