Position controller

Parameter
Address
Name / setting range / [default setting]
Information
0x2980
Position controller gain
0.00 ... [28.40] ... 10000.00 1/s
Setting of the position controller gain.
0x2982
Position controller output signal limitation
0 ... [480000] ... 480000 rpm
Setting of the output signal limitation.