Process input data

The following diagram demonstrates the relationship of the parameters 0x6048:001 and 0x6048:002.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x6042
Set speed
-32768 ... [0] ... 32767 rpm
Set speed (velocity mode).
0x6046:001
Speed limits: Min. speed
0 ... [0] ... 480000 rpm
Min. speed (velocity mode).
0x6046:002
Speed limits: Max. speed
0 ... [2147483647] ... 2147483647 rpm
Max. speed (velocity mode).
0x6048:001
Acceleration ramp: CiA acceleration: Delta speed
0 ... [3000] ... 2147483647 rpm
CiA acceleration: Delta speed
0x6048:002
Acceleration ramp: CiA acceleration: Delta time
0 ... [10] ... 65535 s
CiA acceleration: Delta time
0x6049:001
Deceleration ramp: CiA deceleration: Delta speed
0 ... [3000] ... 2147483647 rpm
CiA deceleration: Delta speed
0x6049:002
Deceleration ramp: CiA deceleration: Delta time
0 ... [10] ... 65535 s
CiA deceleration: Delta time
0x6071
Set torque
-3276.8 ... [0.0] ... 3276.7 %
Setting of the setpoint torque for the torque operating modes.
–
100 % = Rated motor torque 0x6076
 
The inverter does not support the CiA 402 torque mode.