Acknowledgement signals
Error acknowledgement (AIE)
Errors require acknowledgement with the AIE signal.
Error acknowledgement via the safety bus with the "AIE" bit:
–
Acknowledgement with bit change 0
↗
1.–
The bit must be set for at least one safety bus cycle.
Restart acknowledgement (AIS)
After a stop function has been executed, the restart requires an acknowledgement with the AIS signal if "acknowledged restart" is set:
Restart acknowledgement via the safety bus with the "AIS" bit:
–
Acknowledgement with bit change 0
↗
1.–
The bit must be set for at least one safety bus cycle.