0x500A:005
|
TA axis parameter: Status word
|
|
|
Bit 0
|
Virtual mode active
|
|
Bit 1
|
Axis ready
|
|
Bit 2
|
Axis enabled
|
|
Bit 3
|
Warning active
|
|
Bit 4
|
Error active
|
|
Bit 5
|
Home position detected
|
|
Bit 6
|
Software limit switches enabled
|
|
Bit 7
|
Software limit switch positive
|
|
Bit 8
|
Software limit switch negative
|
|
Bit 9
|
Hardware limit switch positive
|
|
Bit 10
|
Hardware limit switch negative
|
|
Bit 11
|
STO active
|
|
Bit 12
|
Brake opened
|
|
Bit 13
|
Application quick stop active
|
|
Bit 14
|
Limitation active
|
|
Bit 16
|
"Following error" warning active
|
|
Bit 17
|
"Following error" error active
|
|
Bit 18
|
Homing active
|
|
Bit 19
|
Homing switch for touch probe reached
|
|
Bit 21
|
Manual jog active
|
|
Bit 22
|
Standstill active
|
|
Bit 23
|
Set position reached
|
|
Bit 24
|
Software limit switches switched off
|
|
0x500A:010
|
TA axis parameter: Actual position
|
|
0x500A:011
|
TA axis parameter: Actual velocity
–
Read only: x.xxxx unit/s
|
|
0x500A:012
|
TA axis parameter: Actual acceleration
–
Read only: x.xx unit/s²
|
|
0x500A:014
|
TA axis parameter: Position setpoint
|
|
0x500A:015
|
TA axis parameter: Velocity setpoint
–
Read only: x.xxxx unit/s
|
|
0x500A:016
|
TA axis parameter: Acceleration setpoint
–
Read only: x.xx unit/s²
|
|
0x5030:205
|
Table Positioning: Interface dialog
|
|
0x5030:207
|
Table Positioning: Signal flow dialog
|
|
0x5032:011
|
Diagnostic profile parameters: Active Profile
|
|
0x5032:012
|
Diagnostic profile parameters: Acceleration
–
Read only: x.xx unit/s²
|
|
0x5032:013
|
Diagnostic profile parameters: Deceleration setpoint
–
Read only: x.xx unit/s²
|
|
0x5032:014
|
Diagnostic profile parameters: Jerk
–
Read only: x.xx unit/s³
|
|
0x5032:015
|
Diagnostic profile parameters: Velocity
–
Read only: x.xxxx unit/s
|
|
0x5032:020
|
Diagnostic profile parameters: Position
|
|
0x5032:025
|
Diagnostic profile parameters: Selected profile
|
|
0x5032:027
|
Diagnostic profile parameters: Velocity override
|