Diagnostics

Parameter
Address
Name / setting range / [default setting]
Information
0x500A:005
TA axis parameter: Status word
–
Read only
 
Bit 0
Virtual mode active
Bit 1
Axis ready
Bit 2
Axis enabled
Bit 3
Warning active
Bit 4
Error active
Bit 5
Home position detected
Bit 6
Software limit switches enabled
Bit 7
Software limit switch positive
Bit 8
Software limit switch negative
Bit 9
Hardware limit switch positive
Bit 10
Hardware limit switch negative
Bit 11
STO active
Bit 12
Brake opened
Bit 13
Application quick stop active
Bit 14
Limitation active
Bit 16
"Following error" warning active
Bit 17
"Following error" error active
Bit 18
Homing active
Bit 19
Homing switch for touch probe reached
Bit 21
Manual jog active
Bit 22
Standstill active
Bit 23
Set position reached
Bit 24
Software limit switches switched off
0x500A:010
TA axis parameter: Actual position
–
Read only: x.xxxx Unit
 
0x500A:011
TA axis parameter: Actual velocity
–
Read only: x.xxxx unit/s
 
0x500A:012
TA axis parameter: Actual acceleration
–
Read only: x.xx unit/s²
 
0x500A:014
TA axis parameter: Position setpoint
–
Read only: x.xxxx Unit
 
0x500A:015
TA axis parameter: Velocity setpoint
–
Read only: x.xxxx unit/s
 
0x500A:016
TA axis parameter: Acceleration setpoint
–
Read only: x.xx unit/s²
 
0x5030:205
Table Positioning: Interface dialog
–
Read only
 
0x5030:207
Table Positioning: Signal flow dialog
–
Read only
 
0x5032:011
Diagnostic profile parameters: Active Profile
–
Read only
 
0x5032:012
Diagnostic profile parameters: Acceleration
–
Read only: x.xx unit/s²
 
0x5032:013
Diagnostic profile parameters: Deceleration setpoint
–
Read only: x.xx unit/s²
 
0x5032:014
Diagnostic profile parameters: Jerk
–
Read only: x.xx unit/s³
 
0x5032:015
Diagnostic profile parameters: Velocity
–
Read only: x.xxxx unit/s
 
0x5032:020
Diagnostic profile parameters: Position
–
Read only: x.xxxx Unit
 
0x5032:025
Diagnostic profile parameters: Selected profile
–
Read only
 
0x5032:027
Diagnostic profile parameters: Velocity override
–
Read only: x.xx %