Axis parameters

Parameter
Address
Name / setting range / [default setting]
Information
0x500A:020
TA axis parameter: Motion kind
–
Setting can only be changed if the inverter is disabled.
 
0
not defined
1
translatory
2
rotary
0x500A:029
TA axis parameter: Virtual mode
–
Setting can only be changed if the inverter is disabled.
 
With the "Virtual mode" function, the application can be tested without a connected motor. If the function is activated, the set values generated in the application are not forwarded to the drive. The actual values (e.g. position and speed) are generated from the setpoint values.
–
The kinematics parameters have no influence in virtual mode. Only the travel range and cycle length parameters are used for the machine measuring system.
 
0
Inactive
1
Active
0x500A:030
TA axis parameter: Travel range
–
Setting can only be changed if the inverter is disabled.
 
Kinematics parameters
–
The kinematics parameters describe, among other things, the motor side with regard to the mechanics used.
 
0
Modulo
1
Limited
0x500A:031
TA axis parameter: Cycle length
0.0001 ... [360.0000] ... 214748.3647 Unit
–
Setting can only be changed if the inverter is disabled.
 
0x500A:032
TA axis parameter: Feed constant
0.0001 ... [360.0000] ... 214748.3647
–
Setting can only be changed if the inverter is disabled.
 
0x500A:033
TA axis parameter: Gearbox factor - nominator
1 ... [1] ... 4294967295
–
Setting can only be changed if the inverter is disabled.
 
0x500A:034
TA axis parameter: Gearbox factor - denominator
1 ... [1] ... 4294967295
–
Setting can only be changed if the inverter is disabled.
 
0x500A:045
TA axis parameter: Max. velocity
0.0000 ... [0.0000] ... 214748.3647 unit/s
Maximum values for profile parameters.
0x500A:046
TA axis parameter: Max. acceleration
0.00 ... [0.00] ... 21474836.47 unit/s²
0x500A:047
TA axis parameter: Max. jerk
0.00 ... [0.00] ... 21474836.47 unit/s³
0x500A:050
TA axis parameter: Enable software position limits
The adjustable software limit positions are used to limit the travel range on the software side and prevent travel commands from being executed that would result in the permissible travel range being exceeded.
–
If the software limit positions are enabled and these are reached using the "Manual operation" function, for example, the movement is stopped, i.e. the axis is brought to a standstill using the "Stop" function. The software limit positions can then be released in the direction of the permitted travel range.
 
–
In the event of an error, the reaction set in 0x500A:105 is triggered (e.g. output of a warning).
 
0
Inactive
1
Active
0x500A:051
TA axis parameter: Software position limit positive
-214748.3648 ... [0.0000] ... 214748.3647 Unit
0x500A:052
TA axis parameter: Software position limit negative
-214748.3648 ... [0.0000] ... 214748.3647 Unit
0x500A:054
TA axis parameter: Following error monitoring
The following error is the difference between the setpoint position and the actual position. The following error should ideally be "0". If the position control is set optimally, only a minimum following error is formed. The following error is regulated dynamically and does not increase continuously.
However, certain processes require that the following error does not exceed a certain limit value, as otherwise the system part will not reach the defined target position in time, for example. For such processes, two limit values for the following error can be set and activated.
With active monitoring:
–
If the first limit value ("warning threshold") is exceeded, a warning is displayed. However, the current movement of the axis is not interrupted.
 
–
If the second limit value ("error threshold") is exceeded, the reaction set for this monitoring in 0x500A:059 is triggered.
 
0
Inactive
1
Active
0x500A:055
TA axis parameter: Following error: Warning threshold
0.0000 ... [180.0000] ... 214748.3647 Unit
0x500A:056
TA axis parameter: Following error: Error threshold
0.0000 ... [360.0000] ... 214748.3647 Unit
0x500A:057
TA axis parameter: Actual following error
–
Read only: x.xxxx Unit
 
0x500A:058
TA axis parameter: Maximum following error
–
Read only: x.xxxx Unit
 
0x500A:059
TA axis parameter: Response to following error
Associated event ID:
–
34437 | 0x8685 - Following error - Error level exceeded
 
12
Warning
23
Fault
0x500A:070
TA axis parameter: Homing mode
-2
CwTorqueLimit
-1
CcwTorqueLimit
0
SetPositionDirect
1
CcwLimitSwitchCwTP
2
CwLimitSwitchCcwTP
3
CwRpCcwRnTP
5
CcwRpCwRnTP
17
CcwLimitSwitch
18
CwLimitSwitch
19
CwRpCcwRn
21
CcwRpCwRn
33
CcwTP
34
CwTP
0x500A:071
TA axis parameter: Action after "Home position detected"
0
Stop positioning
1
Relative positioning
2
Absolute positioning
0x500A:072
TA axis parameter: Homing: Target position
-214748.3648 ... [0.0000] ... 214748.3647 Unit
Profile parameters for the "Homing" function.
0x500A:073
TA axis parameter: Homing: Velocity 1
0.0000 ... [360.0000] ... 214748.3647 unit/s
0x500A:074
TA axis parameter: Homing: Velocity 2
0.0000 ... [0.0000] ... 214748.3647 unit/s
0x500A:075
TA axis parameter: Homing: Acceleration 1
0.00 ... [720.00] ... 21474836.47 unit/s²
0x500A:076
TA axis parameter: Homing: Acceleration 2
0.00 ... [360.00] ... 21474836.47 unit/s²
0x500A:077
TA axis parameter: Homing: Jerk
0.00 ... [7200.00] ... 21474836.47 unit/s³
0x500A:078
TA axis parameter: Homing: Torque limit
0.00 ... [0.10] ... 21474836.47 Nm
Only for "Referencing to positive stop"
(homing modes CwTorqueLimit [-2] and CcwTorqueLimit [-1]).
The home position is set if the axis is stationary during the locking time and the actual torque is greater than the torque limit.
0x500A:079
TA axis parameter: Homing: Blocking time
0.000 ... [1.000] ... 2147483.647 s
0x500A:080
TA axis parameter: Homing: Touch probe configuration
1
TP1 - positive edge
2
TP1 - negative edge
0x500A:084
TA axis parameter: Home position
-214748.3648 ... [0.0000] ... 214748.3647 Unit
0x500A:090
TA axis parameter: Default control mode
–
Setting can only be changed if the inverter is disabled.
 
0
Position control via motor encoder
1
Position control via load encoder
10
Speed control via motor encoder
0x500A:104
TA axis parameter: Response to hardware limit switch error
Associated event IDs:
–
34434 | 0x8682 - Overrun positive hardware limit switch
 
–
34435 | 0x8683 - Overrun negative hardware limit switch
 
12
Warning
23
Fault > inverter disabled
0x500A:105
TA axis parameter: Response to software position limit error
Associated event IDs:
–
34432 | 0x8680 - Overrun positive software limit
 
–
34433 | 0x8681 - Overrun negative software limit
 
12
Warning
23
Fault > inverter disabled
0x500A:106
TA axis parameter: Response to error "max. values exceeded"
Associated event ID:
–
34454 | 0x8696 - Maximum value exceeded
 
0
No response
12
Warning
23
Fault
0x500A:130
TA axis parameter: Position window size
0.0000 ... [0.0000] ... 214748.3647 Unit
0x500A:131
TA axis parameter: Position window dwell time
0.000 ... [0.000] ... 2147483.647 s
0x500A:135
TA axis parameter: Modulo positioning tolerance window
0.0000 ... [0.0000] ... 214748.3647 Unit
0x500A:136
TA axis parameter: Tolerance window actual position=set position upper limit
0.0000 ... [0.0000] ... 214748.3647 Unit
0x500A:137
TA axis parameter: Tolerance window actual position=set position lower limit
0.0000 ... [0.0000] ... 214748.3647 Unit
0x500A:181
TA axis parameter: Manual jog velocity
0.0000 ... [360.0000] ... 214748.3647 unit/s
Profile parameters for the "Manual operation" function.
0x500A:182
TA axis parameter: Manual jog acceleration
0.00 ... [720.00] ... 21474836.47 unit/s²
0x500A:183
TA axis parameter: Manual jog deceleration
0.00 ... [720.00] ... 21474836.47 unit/s²
0x500A:184
TA axis parameter: Manual jog jerk
0.00 ... [7200.00] ... 21474836.47 unit/s³
0x500A:186
TA axis parameter: Deceleration of Halt
0.01 ... [720.00] ... 21474836.47 unit/s²
Profile parameters for the "Stop" function.
0x500A:187
TA axis parameter: Jerk of Halt
0.00 ... [7200.00] ... 21474836.47 unit/s³
0x500B:033
Load encoder: Gearbox factor - nominator
1 ... [1] ... 4294967295
–
Setting can only be changed if the inverter is disabled.
 
0x500B:034
Load encoder: Gearbox factor - denominator
1 ... [1] ... 4294967295
–
Setting can only be changed if the inverter is disabled.
 
0x500B:035
Load encoder: Load encoder mounting direction
–
Setting can only be changed if the inverter is disabled.
 
0
CW
1
CCW
0x500B:085
Load encoder: Homepos available for absolute encoder
0
Default behaviour
1
Permanently set
0x500B:086
Load encoder: Homing: Offset Position (for Mode 98 or Sub 85)
-214748.3648 ... [0.0000] ... 214748.3647 Unit
0x5020:011
Interface selection: TP1 source
11
Digital input 2, positive edge
12
Digital input 2, negative edge