Process data transfer
–
Process data is cyclically transferred between the EtherCAT master and the slaves (permanent exchange of current input and output data).
–
The transfer of process data is time-critical.
–
The process data serve to control the EtherCAT slaves.
–
The process data can be directly accessed by the master. The data in the PLC, for instance, are directly stored in the I/O area.
–
The contents of the process data are defined via I/O Data mapping (definition of the EtherCAT objects that are to be transmitted cyclically).
–
Process data is not saved in the device.
–
Process data is, e. g. setpoints, actual values, control and status words.
Configuration
–
The available objects can be mapped in the CiA 402 operating mode "CiA: Velocity mode (vl)" (0x6060 (P301.00) = 2) and as dynamic (free) configuration. The contents can be selected from all mappable objects.
–
Standard mapping objects for the CiA 402 operating mode "CiA: Velocity mode (vl)":
Standard mapping
Standard mapping –
Mapping objects for a dynamic (free) assignment:
Dynamic (free) configuration
Dynamic (free) configuration –
Mapping is executed in the master configuration and automatically transferred to the slave.
–
Format: 0xiiiissll (iiii = Index hexadecimal, ss = subindex hexadecimal, ll = data length hexadecimal)