Filtering of the touch probe signal

For the touch probe inputs, a common filter time (debounce time) can be parameterised to debounce the TP signals so that there is no response to external interfering signals.
–
The signal status of the debouncing filter is detected at the TP input and a new value is added to the filter.
 
–
A separate setting for a touch probe is not possible. Thus, the filter time is set for all touch probe inputs.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2500
Touch probe filter time
0 ... [0] ... 1984
The set filter time is automatically taken into account in the touch probe calculation.
The setting "0" deactivates the filter.
Note!
Values can be set directly. When entering a filter time between 0 ... 1984 µs, the value is automatically rounded down internally to the next value that can be set and is shown in the case of read requests.