Compensation of runtime delays

In reality, both the input circuit in the servo inverter and the touch probe sensor have runtime delays (latencies) themselves. These can be taken into account in the calculation of the real trigger time and thus the real position at the trigger time.
In the following figure, the event is detected in the servo inverter at the time
②
. Due to the input circuit and the sensor used, the signal runtime, however, has been delayed. The real physical event has already occurred at time
①
. For compensating this runtime delay, you can set a corresponding delay time for each touch probe channel that is included in the determination of the control cycle and interpolation of the position, see figure in chapter "General mode of operation".
 
"Delay time":
Delay time between the real physical event and the electrical detection.
①
Real physical event
②
Electrical detection of the event in the servo inverter
 
Delay times of the digital input and the required minimum signal duration
The following table lists the typical delay times and the required minimum signal durations for the digital inputs of the servo inverter:
Digital signal
Typical delay time
Minimum signal duration
Rising edge (HIGH pulse)
4 µs
4 µs
Falling edge (LOW pulse)
4 µs
4 µs
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2D00:001
Touch probe (TP) delay time: Touch probe 1 delay time
0.000 ... [0.000] ... 7.000 ms
Setting of the delay time for touch probe 1.
0x2D00:002
Touch probe (TP) delay time: Touch probe 2 delay time
0.000 ... [0.000] ... 7.000 ms
Setting of the delay time for touch probe 2.