Touch probe control word

Control words for configuring the touch probe functionality.
–
CiA control word (Touch probe 1/2): 0x60B8
 
–
Extended control word (Touch probe 3/4, manufacturer-specific): 0x2D02:001
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x60B8
Touch probe settings
0x0000 ... [0x0000] ... 0xFFFF
Control word for configuring the touch probe settings.
Bit  0
TP1 enable
0: deactivate touch probe channel 1.
1: activate touch probe channel 1.
Bit  1
TP1 continous trigger
Event for touch probe channel 1
0: only detect the first event.
1: detect all events.
Bit  2
TP1 trigger with zero pulse
Source for touch probe channel 1
0: digital input 1
1: zero pulse position encoder
Bit  4
TP1 enable pos. edge
0: deactivate scanning.
1: activate scanning.
Bit  5
TP1 enable neg. edge
Bit  8
TP2 enable
0: deactivate touch probe channel 2.
1: activate touch probe channel 2.
Bit  9
TP2 continous trigger
Event for touch probe channel 2
0: only detect the first event.
1: detect all events.
Bit  10
TP2 trigger with zero pulse
Source for touch probe channel 2
0: digital input 2
1: zero pulse position encoder
Bit  12
TP2 enable pos. edge
0: deactivate scanning.
1: activate scanning.
Bit  13
TP2 enable neg. edge