Basic setting
The following parameters must be set for the activation and basic configuration of the holding brake control.
Details
The following settings are possible:
–
Brake mode ①
–
For the automatic operation: ②
–
Brake release time and brake application time
–
Torque feedforward control
–
Test Brake control ③
–
Brake polarity ④
Diagnostic parameters:
–
Display status of the automatic brake identification: 0x2820:004
–
Display signal of the brake logic before the inversion: 0x6041
–
Display status of the holding brake: 0x2820:015
Brake mode
Possible settings: 0x2820:001
–
Manual control via the control word. Das control word depends on the technology application
:
:
–
Technology application CiA 402: 0x6040 Bit 14
–
Speed Control technology application: 0x5030:010 Bit 14
–
0: Close holding brake
–
1: Release holding brake
–
Control via device state machine (automatic operation):
–
The holding brake is controlled as a function of the device state.
–
A torque feedforward control is possible.
The torque is precontrolled for one second. During this time, the actual torque must have reached 90 % of the setpoint torque, otherwise an error is triggered.
–
Response times of the holding brake during release and application can be compensated for.
In the event of an error or when STO ("SafeTorqueOff") is activated, the brake is applied immediately without considering the set brake application time. The inverter immediately changes to the switch-on disabled state.
–
No brake connected (off):
–
holding brake control, automatic brake identification and brake monitoring are deactivated.
Brake polarity
The control logic of the holding brake can be inverted.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2820:001
|
Holding brake control: Brake mode
|
Selecting how the "Release holding brake" command is to be triggered.
|
|
|
0
|
Automatically (via device state)
|
||
|
1
|
Manually
|
||
|
2
|
Off
|
The holding brake is deactivated.
|
|
|
0x2820:002
|
Holding brake control: Brake closing time
0 ... [100] ... 10000 ms
|
Application time (engagement time) of the holding brake.
–
Only effective in automatic operation.
|
|
|
0x2820:003
|
Holding brake control: Brake opening time
0 ... [100] ... 10000 ms
|
Release time (disengagement time) of the holding brake.
–
Only effective in automatic operation.
|
|
|
0x2820:004
|
Holding brake control: Brake detection
–
Read only
|
When 0x2825 = 4 (Manual control mode) and the device state changes from "switched-on" to "operation enabled", it is detected automatically whether a holding brake is connected. The brake identification is repeated after every controller enable.
|
|
|
0
|
Detection not started
|
||
|
1
|
Detection running
|
||
|
2
|
No brake detected
|
||
|
3
|
Brake detected
|
||
|
4
|
Detection not possible
|
The holding brake control is switched off.
|
|
|
0x2820:005
|
Holding brake control: Brake polarity
|
The control logic of the holding brake can be inverted.
|
|
|
0
|
Normal
|
||
|
1
|
Inverted
|
||
|
0x2820:006
|
Holding brake control: Brake error response
|
Selection of the response for holding brake monitoring.
In the triggered state, the holding brake is monitored cyclically for the presence of brake current.
After the brake is connected, the establishment of the brake current is subject to a time delay in accordance with the inductance. Consequently, there is a slight delay in detecting wire breakage, a terminal short-circuit or a missing brake supply.
The response set here occurs when monitoring is triggered.
Note:
The brake is not monitored unless it is triggered.
|
|
|
0
|
No fault
|
||
|
1
|
Fault
|
||
|
2
|
Warning
|
||
|
0x2820:015
|
Holding brake control: Brake status
–
Read only
|
||
|
0
|
Brake closed
|
Holding brake is applied.
|
|
|
1
|
Brake released
|
Holding brake is released.
|
|
|
0x2820:019
|
Holding brake control: Brake opening time test signal
0 ... [500] ... 10000 ms
|
Setting of the brake opening time when the test signal is transmitted (Brake control word bit 0 = 1).
|
|
|
0x2820:023
|
Holding brake control: Control configuration
|
Selection of which output signal is to be used to control the holding brake.
|
|
|
0
|
Via internal brake module
|
The holding brake is controlled via the internal brake module and the brake output X106.
–
The presence of the external 24 V supply for the brake output is monitored.
–
An open-circuit detection is active.
–
A parameterized voltage reduction is active.
|
|
|
1
|
Via external module at X106
|
The brake output X106 controls a relay or power contactor which switches the brake supply.
|
|
|
2
|
Via external module at DIx
|
The holding brake is controlled via the trigger "Release holding brake [115]".
–
This trigger must be assigned to a digital output. The digital output in turn controls a relay or power contactor which switches the brake supply.
–
The digital output is not suitable for direct control of a holding brake!
–
If, instead of an electrically releasing (self-holding) holding brake, an electrically holding (self-releasing) holding brake is to be controlled, a signal inversion must be set for the digital output used!
|
|