0x6076
|
Rated motor torque
0.001 ... [0.600] ... 100000.000 Nm
–
Setting can only be changed if the inverter is disabled.
|
The rated motor torque to be set here serves as a reference value for different parameters with a setting/display of a torque value in percent.
Example:
–
Rated motor torque = 1.65 Nm
–
Max. torque 0x6072 = 250 % Rated motor torque = 4.125 Nm
|
|
0x6077
|
Actual torque
|
Display of the actual torque.
–
100 % = Rated motor torque 0x6076
|
|
0x60E0
|
Positive torque limit
0.0 ... [100.0] ... 3276.7 %
|
Positive torque limit source for speed control with torque limitation.
–
100 % = Rated motor torque 0x6076
–
The value is taken from the application: 0x500A:128.
|
|
0x60E1
|
Negative torque limit
0.0 ... [100.0] ... 3276.7 %
|
Negative torque limit source for speed control with torque limitation.
–
100 % = Rated motor torque 0x6076
–
The value is taken from the application: 0x500A:129.
|