Safety limits

The inverter has functions for supporting the safety technology. Depending on the required safety function, automatic intervention in the setpoint value generation of the axis takes place.
 
When safety engineering is used in coupled axes, it might be required that a requested safety function does not respond in the single axes but that the responses are recognized centrally. The virtual master is able to recognize the response.
The following safety functions can be restricted or deactivated:
Safe torque off (STO) 
Safe stop 1 (SS1) 
Safe stop 2 (SS2) 
Safely-limited speed (SLS) 1 ... 4 
Safe direction (SDI) positive/negative 
The requested safety function is displayed in the Status limiter parameter. 0x500D:163
It can be deactivated in the Deactivate safety functions parameter. 0x500D:162
The axis does not affect the setpoint if the functions are deactivated.
 
Safe stop 1 (SS1) / Safe stop 2 (SS2)
Limited stop 1
Limited stop 2
Status display 0x500D:163 bit 1
Status display 0x500D:163 bit 2
Quick stop application - deceleration 0x500A:048
Quick stop application - deceleration 0x500A:048
Quick stop application - jerk 0x500A:049
Quick stop application - jerk 0x500A:049
After standstill has been reached, the drive is disabled.
The drive is braked to standstill with the parameters Quick stop application - deceleration and Quick stop application - jerk.
After standstill has been reached, the position control of the drive remains active.
 
Safely limited speed (SLS) 1 ... 4
The following parameters limit the speeds and set delay times of the axis:
Speed
Deceleration time
Limited speed 1
Limited speed 2
Limited speed 3
Limited speed 4
–
If the current setpoint speed exceeds the value set for the requested limited speed, the setpoint speed is reduced to the requested limited speed within the parameterized delay time.
 
–
If several limited speeds are requested at the same time, the lowest speed is reduced with the highest deceleration.
 
Status display in Status limiter parameter.0x500D:163, bit 4 ... Bit 7.
 
Master/slave coupling
In the event of an active master/slave coupling e. g. synchronism or cam profiler application, the speed is not reduced automatically in the default setting. The speed is usually automatically reduced by the master axis.
The automatic speed reduction is activated via the Follower - response to SLSparameter. 0x500D:1600x500D:160
If the automatic speed reduction is activated, the cyclically specified setpoints are reduced to the limited speed. The synchronism of the master axis cannot be guaranteed anymore.
If an offset between master and slave occurs, it will be removed automatically by deactivating the parameter. 0x500D:159
An excessive speed due to a following error compensation is avoided by limiting the setpoints at the speed controller input. 0x500D:161
 
Parameter
Address
Name / setting range / [default setting]
Information
0x500D:150
SLS1
0.0000000000 ... [0.0000000000] ... 2147483647.0000000000
0x500D:151
SLS1 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500D:152
SLS2
0.0000000000 ... [0.0000000000] ... 2147483647.0000000000
0x500D:153
SLS2 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500D:154
SLS3
0.0000000000 ... [0.0000000000] ... 2147483647.0000000000
0x500D:155
SLS3 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500D:156
SLS4
0.0000000000 ... [0.0000000000] ... 2147483647.0000000000
0x500D:157
SLS4 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500D:160
Follower - Response to SLS
false
Inactive
true
Active
0x500D:161
Speed controller limitation (SLS)
false
Inactive
true
Active
0x500D:162
Deactivate safety interface
0x00000000 ... [0x0000003E] ... 0xFFFFFFFF
Bit  1
Ignore SS1 request
Bit  2
Ignore SS2 request
Bit  3
Ignore SLS1 - SLS4 request
Bit  4
Ignore SDI request
Bit  5
Ignore SBC request
0x500D:163
Limiter call
–
Read only
 
Bit  0
STO active
Bit  1
SS1 active
Bit  2
SS2 active
Bit  3
SOS active
Bit  4
SLS1 active
Bit  5
SLS2 active
Bit  6
SLS3 active
Bit  7
SLS4 active
Bit  8
SDIpos active
Bit  9
SDIneg active