Setting

Parameter
Address
Name / setting range / [default setting]
Information
0x28A8
OMS Source
–
Safety parameter (+Safety parameter list+)
 
Selection of the trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
3
SD-In3
4
SD-In4
13
S-Bus
0x28A9:001
OMS: Stop function
–
Safety parameter (+Safety parameter list+)
 
Definition of the stop function in special operation.
0
STO
1
SS1
2
SS2
0x28A9:002
OMS: Motion function
–
Safety parameter (+Safety parameter list+)
 
Definition of the motion function in special operation.
3
SLS1
4
SLS2
5
SLS3
6
SLS4
11
Free mode
0x28A9:003
OMS: Function at low level
–
Safety parameter (+Safety parameter list+)
 
Function that is executed at LOW level on the safe input with the OMS function.
CAUTION!
According to the closed-circuit principle, no additional danger may emanate from the parameterization!
0
Normal operation
1
Special operation
0x28AA
OMS "OMS active" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "OMS active" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic
0x28CA:003
SLI: Increment size special operation
0 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Number of increments for safely limited increment in special operation.
Number = 0 deactivates the function.