0x2362:007
|
Active EtherCAT settings: Tx length
|
Display of the length of the transmitted cyclic data in bytes.
|
|
0x2362:008
|
Active EtherCAT settings: Rx length
|
Display of the length of the received cyclic data in bytes.
|
|
0x2368
|
EtherCAT status
|
Display of the current network status.
|
|
0
|
|
|
|
1
|
Initialization
|
Network initialization is active.
–
No PDO/SDO transmission.
–
Device identification is possible by network scan.
|
|
2
|
Pre-Operational
|
The network is active.
–
SDO transmission (CoE communication via mailbox) is possible.
–
No PDO transmission.
|
|
3
|
Bootstrap
|
Is not supported.
|
|
4
|
Safe-Operational
|
–
SDO transmission (CoE communication via mailbox) is possible.
–
PDO transmission: – The input data in the process image are updated. – The output data from the process image is invalid and is not transferred to the application.
|
|
8
|
Operational
|
Normal operation
–
PDO/SDO transmission is possible.
–
• The output data from the process image is valid and is transferred to the application.
|
|
0x2369
|
EtherCAT error
|
Bit coded display of EtherCAT errors.
|
|
Bit
0
|
Watchdog elapsed
|
|
|
Bit
2
|
Invalid configuration
|
|
Bit
3
|
Stack init error
|
|
Bit
4
|
Invalid process data
|