Position controller

Equation for calculating the gain
The automatic calculation is made via the parameter 0x2822:015 = 1.
Parameter
Symbol
Description
Dimension unit
Vp
Position controller gain
Hz
0x2985:001 ... 0x2985:011
Vp(n)
Speed-dependent Vp adaptation
TFilter
Filter time constant - actual speed value
s
-
Tcurrent controller
Equivalent time constant of the current control loop = 0.0005 s
(500 µs)
s
 
Instability of the position control loop due to too high dynamic performance of the speed controller
The following countermeasure must be taken if the following error cannot be reduced to acceptable values while setting the position controller:
 
1.
Reduce speed controller by the factor 2 and slowly increase the position controller until it gets slightly unstable again.
 
2.
Reduce the position controller slightly and increase the speed controller until the position control loop gets slightly unstable again.
 
3.
Repeat these steps until the following error is reduced to acceptable values.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2980
Position controller gain
0.00 ... [28.40] ... 10000.00 1/s
Setting of the position controller gain.
0x2981
Position controller gain adaption
0.00 ... [100.00] ... 200.00 %
Setting of the percentage adaptation for the position controller gain.
0x2982
Position controller output signal limitation
0.00 ... [480000.00] ... 480000.00 rpm
Setting of the output signal limitation.
0x2983
Actual position start value
-2147483647 ... [0] ... 2147483647
Specifying a new actual position.
0x2984
Mode for setting the actual position
Selection of the mode for setting or shifting the actual position.
0
Absolute
Actual position = Actual position start value (0x2983)
1
Relative
Actual position = actual position + Actual position start value (0x2983)
0x2986
Resulting gain adaption
–
Read only: x.xx %
 
Display of the resulting gain after being adapted.