ASM field weakening controller
Since the controlled system gain changes with the speed, the field weakening controller is corrected via the speed.
The automatic calculation is made via the parameter 0x2822:017 = 1.
Calculation of the gain
Calculation of the reset time
|
Parameter
|
Symbol
|
Description
|
Dimension unit
|
|
Vp
|
Gain of the field weakening controller
|
Vs / A
|
|
|
-
|
VPath_Fs
|
Gain of the control path
|
|
|
-
|
P
|
Number of pole pairs
|
rpm
|
|
-
|
ntransition
|
Speed at which the field weakening is approximately initiated.
|
|
|
Tn
|
Reset time of the field weakening controller
|
s
|
|
|
-
|
TEF
|
Filter time constant of the field control loop
|
|
|
TFilter
|
Filter time constant for the required voltage
|
s
|
|
|
-
|
Tr
|
Motor rotor time constant
|
|
|
-
|
Lr
|
Motor rotor resistance (ASM)
|
|
|
Lh
|
Mutual motor inductance (ASM)
|
H
|
|
|
Lss
|
Motor stator leakage inductance (ASM) or motor leakage inductance (SM)
|
H
|
|
|
Rr
|
Motor rotor resistance
|
Ω
|
Parameter