Supported operating modes

The inverter supports the following CiA 402 operating modes:
 
A CiA 402 operating mode can be activated via 0x6060.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x6060
CiA: Operation mode
CiA: Operation mode
-13
MS: Manual jog open loop (MOL)
Manufacturer-specific manual control
-12
MS: Pole position identification (PPI)
Manufacturer-specific pole position identification (PLI)
0
No selection
No selection
2
CiA: Velocity mode (vl)
8
CiA: Cyclic sync position (csp)
9
CiA: Cyclic sync velocity mode (csv)
10
CiA: Cyclic sync torque mode (cst)
0x6061
CiA: Active operation mode
–
Read only
 
CiA: Active operation mode
-13
MS: Manual jog open loop (MOL)
Manufacturer-specific manual control
-12
MS: Pole position identification (PPI)
Manufacturer-specific pole position identification (PLI)
-11
Identification
-10
Test mode
0
No selection
No selection
2
CiA: Velocity mode (vl)
8
CiA: Cyclic sync position (csp)
9
CiA: Cyclic sync velocity mode (csv)
10
CiA: Cyclic sync torque mode (cst)
0x6502
Supported drive modes
–
Read only
 
Bit coded display of the operating modes supported.
Bit  1
CiA: Velocity mode
1 = CiA: velocity mode is supported.
Bit  7
Cyclic sync position mode
1 ≡ Cyclic sync position mode is supported.
Bit  8
Cyclic sync velocity mode
1 ≡ Cyclic sync velocity mode is supported.
Bit  9
Cyclic sync torque mode
1 ≡ Cyclic sync torque mode is supported.