Operation mode "Manual Jog"

Parameter
Address
Name / setting range / [default setting]
Information
0x2C67:001
MOL settings for 0x6060: Current setpoint 1
0 ... [71] ... 200 %
0x2C67:002
MOL settings for 0x6060: Frequency 1
-500.0 ... [1.0] ... 500.0 Hz
0x2C67:003
MOL settings for 0x6060: Current 1 - ramp time
10 ... [10] ... 1000 ms
0x2C67:004
MOL settings for 0x6060: Frequency 1 - ramp time
0 ... [200] ... 10000 ms
0x2C67:005
MOL settings for 0x6060: Starting angle 1
-179.9 ... [0.0] ... 179.9 °
0x2C67:006
MOL settings for 0x6060: Stopping time 1
0.0 ... [10000.0] ... 10000.0 s
–
Setting can only be changed if the inverter is disabled.
 
0x2C67:011
MOL settings for 0x6060: Current setpoint 2
0 ... [71] ... 200 %
0x2C67:012
MOL settings for 0x6060: Frequency 2
-500.0 ... [5.0] ... 500.0 Hz
0x2C67:013
MOL settings for 0x6060: Current 2 - ramp time
10 ... [10] ... 1000 ms
0x2C67:014
MOL settings for 0x6060: Frequency 2 - ramp time
0 ... [1000] ... 10000 ms
0x2C67:015
MOL settings for 0x6060: Starting angle 2
-179.9 ... [0.0] ... 179.9 °
0x2C67:016
MOL settings for 0x6060: Stopping time 2
0.0 ... [10000.0] ... 10000.0 s
–
Setting can only be changed if the inverter is disabled.