Basic setting

Set the following parameters.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x605A
CiA: Quick stop mode
Device status after exiting the quick stop ramp.
2
Ramp > switch on disabled
Automatic change to the "Switch-on inhibited" device state.
–
The "Quick stop active [54]" status is reset to FALSE after ramp-down to standstill.
 
6
Ramp > quick stop active
The inverter remains in the "Quick stop active" device state.
–
The "Quick stop active [54]" status remains TRUE until the "Quick stop" function is activated.
 
0x605B
Shutdown option code
Defines the transition from the status "Operation enabled" to "Ready to start".
0
Disable drive function
0: Immediate inverter disable (standard setting)
1
Slow down on quick stop ramp and disable drive function
1: "Quick stop" with subsequent inverter disable.
0x605E
CiA: Response to minor faults
Set the transition response for slight errors.
-3
Advanced quick stop (hoist)
Behavior in case of 'Error - motor encoder':
Immediate change to the 'Error' status.
The inverter is disabled immediately.
The motor has no torque.
When the automatic brake is activated, a brake controlled by the inverter is applied. 0x2820:001
All other minor errors behave in the same way as selection -2.
-2
Advanced quick stop
If possible, the motor is brought to a standstill with the "quick stop" function.
If this is not possible (e.g. in the event of an encoder error), a braking torque is generated with reverse current braking or short-circuit braking.
0
No transition response
The motor is no longer energized.
2
Quick stop
The motor is brought to a standstill with the "quick stop" function.
0x2826
Timeout for error response -> quickstop
0 ... [4] ... 100 s
If the transition reaction specified in CiA: Response to minor faults is not completed within this time, the inverter changes to the 'Error' state.
The motor is no longer energized.
When the automatic brake is activated, a brake controlled by the inverter is applied. 0x2820:001
0x607E
Polarity
0 ... [0] ... 0
–
Setting can only be changed if the inverter is disabled.
 
Setting of the polarity of the position setpoint.
0 ≡ the position setpoint is interpreted as entered in 0x607A (Set position).
0x6085
Quick stop deceleration
0 ... [2147483647] ... 2147483647
Change in velocity used for deceleration to a standstill if quick stop is activated.