Status signals

Parameter
Address
Name / setting range / [default setting]
Information
0x5040:110
Status signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Bit  0
Ready for operation
Axis ready to be switched on.
Bit  1
Homing active
Homing is active.
Bit  2
Operation enabled
Axis is enabled.
Bit  3
Fault
An error is active.
Bit  4
Homing done
Homing was completed successfully.
Bit  5
Application quick stop active
Quick stop was triggered.
Bit  6
Manual jog active
Manual operation is active.
Bit  7
Warning
A warning is active.
Bit  8
Halt active
A stop was triggered in the application.
Bit  9
Motorcontrol in limitation
The motor control is in limitation.
Bit  10
Set position reached
Actual position = setpoint position
Bit  11
Abort busy
The active movement is canceled.
Bit  12
Standstill
Standstill reached.
Bit  13
Direction of rotation inverted
Direction of rotation is inverted.
Bit  14
Brake opened
The holding brake is open.
Bit  15
STO active
Safe Torque Off is active.
Bit  16
Clutch closed
Position clutch closed.
Bit  17
Clutching in or declutching active
Clutch function active.
Bit  18
Mark detected
Mark detected.
Bit  19
Mark correction active
Correction movement is active.
Bit  20
Mark error is limited
Position error limited to maximum value.
Bit  21
Mark not detected
No mark within the mark window.
Bit  22
Mark window was teached
Homing of the mark window is completed.
Bit  23
Tool correction active
Correction of the tool is active.
Bit  24
Tool mark window was teached
Homing of the tool mark window is completed.
Bit  25
Status bit 25 (reserved)
Bit without function
Bit  26
Status bit 26 (reserved)
Bit  27
Status bit 27 (reserved)
Bit  28
Status bit 28 (reserved)
Bit  29
Status bit 29 (reserved)
Bit  30
Status bit 30 (reserved)
Bit  31
Status bit 31 (reserved)
0x5040:111
Status signals limiter
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Extended Safety - status of the monitoring functions
Bit  0
STO active
Safe torque off (STO) active.
The axis is safely switched to torqueless operation.
Bit  1
SS1 active
Safe stop 1 (SS1) active.
Subsequently, the drive is torqueless (STO).
Bit  2
SS2 active
Safe stop 2 (SS2) active.
The drive then changes to the safe operational stop (SOS).
Bit  3
SOS active
Safe operational stop (SOS) active.
The reached position is actively held.
Bit  4
SLS1 active
Safely limited speed (SLS1) active.
The travel profile changes according to the parameters set for it.
Bit  5
SLS2 active
Safely limited speed (SLS2) active.
The travel profile changes according to the parameters set for it.
Bit  6
SLS3 active
Safely limited speed (SLS3) active.
The travel profile changes according to the parameters set for it.
Bit  7
SLS4 active
Safely limited speed (SLS4) active.
The travel profile changes according to the parameters set for it.
Bit  8
SDpos active
Safe direction (SDI) active.
Only the positive direction is allowed.
Bit  9
SDneg active
Safe direction (SDI) active.
Only the negative direction is allowed.
Bit  10
SLI active
Safely limited increment (SLI) active.
A maximum permissible change in position is monitored.
Bit  11
SSE active
Safe stop emergency (SSE) active.
Bit  12
ES active
Enable switch (ES) active.
The stop functions in special mode are overridden.
Bit  13
OMS active
Operation mode selector (OMS) active.
Special operation is active.
0x5040:112
Actual velocity
-214748.3648 ... [0.0000] ... 214748.3647
Display of the actual velocity
0x5040:114
Error code
0 ... [0] ... 4294967295
Display of the current error number.
0x5040:115
Actual torque
-214748.3648 ... [0.0000] ... 214748.3647 Nm
Display of the actual torque
0x5040:117
Display value 2
0 ... [0] ... 4294967295
Display of the monitor signal "Display value 2"
Selection: 0x5040:007