Hardware limit switches

Connection of the hardware limit switches
The hardware limit switches are assigned to the digital inputs via the Positive hardware limit source and Negative hardware limit source parameters.
–
Positive hardware limit source 0x5020:004
 
–
Negative hardware limit source 0x5020:005
 
The limit switch evaluation responds to a positive edge.
If the limit switch connections for the digital inputs used are to be fail-safe, change the terminal polarity of the corresponding digital inputs.
 
Fig. 1: “Hardware limit switch” selection
 
Activate the hardware limit switches
If either of the hardware limit switches is activated (TRUE signal is applied to input), the parameterized error response is executed. 0x500A:104.
The error message "HWLimitPos" or "HWLimitNeg" is output, irrespective whether the axis rotates and in which direction it moves.
Reset error to retract the limit switch.
After the error has been reset, only travel requests in the opposite direction are possible. Travel requests in the direction of the limit switch are aborted in the event of an error.
 
Diagnostics
Status word of the technology application 0x500A:005, bits 9 and 10
 
Parameter
Address
Name / setting range / [default setting]
Information
0x500A:104
Response to hardware limit switch error
19
Fault > Application quick stop > Quick stop
21
Fault> Application quick stop > Inverter disabled
0x5020:004
Source of positive hardware limit switch
Selection of the digital inputs for the positive hardware limit switch.
0
FALSE
Specification of the digital inputs for the positive hardware limit switch.
1
TRUE
2
Digital input 1
3
Digital input 2
4
Digital input 3
5
Digital input 4
0x5020:005
Source of negative hardware limit switch
Selection of the digital inputs for the negative hardware limit switch.
0
FALSE
Specification of the digital inputs for the negative hardware limit switch.
1
TRUE
2
Digital input 1
3
Digital input 2
4
Digital input 3
5
Digital input 4