Continuous positioning

This mode does not require a predefined position, but instead follows the profile parameters.
–
The acceleration and the deceleration are based on the profile parameters real acceleration and real deceleration.
 
–
The travel direction is defined by the sign of the travelling speed. A positive value signifies travel in the clockwise direction.
 
The travel is stopped by means of a control bit:
–
Abort positioning, 0x5030:010, bit 11 = TRUE
 
–
Stop, 0x5030:010, bit 8 = TRUE