Homing process

Parameter
Address
Name / setting range / [default setting]
Information
0x500A:070
Homing mode
-2
CwTorqueLimit
-1
CcwTorqueLimit
0
SetPositionDirect
1
CcwLimitSwitchCwTP
2
CwLimitSwitchCcwTP
3
CwRpCcwRnTP
5
CcwRpCwRnTP
17
CcwLimitSwitch
18
CwLimitSwitch
19
CwRpCcwRn
21
CcwRpCwRn
33
CcwTP
34
CwTP
97
98
99
Reset home position
0x500A:071
Action after "Home position detected"
Action of the drive after the home position has been detected.
0
Stop positioning
The drive stops.
1
Relative positioning
Relative positioning by the distance set in 0x503F:072.
2
Absolute positioning
Absolute positioning to the position set in 0x503F:072
0x500A:078
Homing: Torque limit
0.00 ... [0.10] ... 21474836.47 Nm
Only for "homing to end stop":
Homing mode
–
0x6098 = [-2] (CwTorqueLimit)
 
–
0x6098 = [-1] (CcwTorqueLimit)
 
The reference is set when the drive is at standstill during the blocking time and the actual torque is greater than the torque limit.
0x500A:079
Homing: Blocking time
0.000 ... [1.000] ... 2147483.647 s
0x500A:080
Homing: Touch probe configuration
Selection of the source for setting the home position
0
External source
1
TP1 - positive edge
Edge of the touch probe sensor at DI1
2
TP1 - negative edge
3
TP1 - any edge
4
TP1 - zero pulse
Zero pulse of the motor encoder
5
11
TP2 - positive edge
Edge of the touch probe sensor at DI2
12
TP2 - negative edge
13
TP2 - any edge
14
TP2 - zero pulse
Zero pulse of the motor encoder
15
21
TP3 - positive edge
Edge of the touch probe sensor at DI3
22
TP3 - negative edge
23
TP3 - any edge
24
TP3 - zero pulse
Zero pulse of the motor encoder
25
31
TP4 - positive edge
Edge of the touch probe sensor at DI4
32
TP4 - negative edge
33
TP4 - any edge
34
TP4 - zero pulse
Zero pulse of the motor encoder
35
0x500A:084
Home position
-214748.3648 ... [0.0000] ... 214748.3647