Absolute extension and compression factor of the master axis
Connection of the scaling factor lrSetScalingX < 0 to the master axis during runtime in the master cycle
-
Upper blue curve: master axis
In the master cycle, the lrSetScalingX input = 0.5 (range 2).
-
Red curve: x axis with the eScalingModeX mode = 1 (instant absolute)
The lrSetScalingX scaling factor has an immediate effect on the course of the x position and the x speed. The position and the speed of the x axis jump. The factor is multiplied in the calculation.
x_pos = Master_pos * lrSetScalingX
x_vel = Master_vel * lrSetScalingX
-
Lower blue curve: x axis with the eScalingModeX mode = 3 (profile generator absolute)
The lrSetScalingX scaling factor also has a multiplicative effect on the position and the speed of the x axis. However, the difference is that the step change in the x position and in the x speed is extended via the ramp generator.
Parameters to be set
The parameters to be set are located in the L_TS2P_scPar_FlexCamHigh structure.
-
scPar.eScalingModeX , data type: L_TS2P_ScalingMode, initial value: "x_zero"
-
scPar.lrSetOffsetScalingXVel , data type: LREAL, initial value: 100
-
scPar.lrSetOffsetScalingXAcc , data type: LREAL, initial value: 1 000
-
scPar.lrSetOffsetScalingXDec , data type: LREAL, initial value: 1 000
-
scPar.lrSetOffsetScalingXJerk , data type: LREAL, initial value: 1 000 000