Disengage cam disc in clutch mode "DistAbsolute"
The cam disc is disengaged from the guide position to the disengagement position based on a 5th degree polynomial.
The parameter lrSyncOutDistX defines the distance over which the cam disc is moved to the disengagement position. Disengagement can only take place when the master axis is in motion.
If the master axis is stopped during the decoupling process, the coupling also stops.
As soon as the master axis resumes its movement, the decoupling process of the cam disc is automatically continued.
|
Clutch mode eClutchMode |
Description |
|---|---|
|
L_TS2P_ClutchMode.DistAbsolute |
The clutch is disengaged to the standstill position via a cam disc with a 5th order polynomial. |
|
L_TS2P_ClutchMode.InstantAbsolute |
The clutch is opened abruptly. |
Parameters to be set
The parameters to be set are located in the scPar structure.
|
Parameters Data |
Description |
|---|---|
|
eClutchMode L_TS2P_ClutchMode |
Initial value: DistAbsolute |
|
lrClutchInDistX LREAL |
Initial value: 100 |
|
lrClutchOutDistX LREAL |
Initial value: 0
|