Engage cam disc in "Instant absolute" coupling mode
The position, speed, and acceleration of the control value coupling are set directly to the position of the control value axis. To avoid irregularities in the drive movement, the slave axis must not be in the CAMMING state (SyncIn coupling closed) before the engagement process. Otherwise, the FlexCam axis will jump to a new position.
In this case, the eClutchMode parameter must be set to the value "InstantAbsolute".
Parameters to be set
The parameters to be set are located in the scPar structure.
|
Parameter Data |
Description |
|---|---|
|
eClutchMode L_TS2P_ClutchMode, |
Initial value: DistAbsolute |