Executing the cam once
The xCamCyclic parameter is set to FALSE to execute the cam once, i.e. after reaching the cam end point ( xEndOfProfile output = TRUE), the master axis stops while the setpoint for the slave axis remains unchanged.
If the master position is outside the defined cam, the last valid value for the slave axis is output.
Parameters to be set
The parameters to be set are located in the L_TS2P_scPar_FlexCamHigh structure.
-
scPar.xCamCyclic , BOOL, initial value: TRUE
Executing the cam once
|
No |
xSyncIn |
xCammingBusy |
xEndOfProfile |
Info |
|---|---|---|---|---|
|
A |
FALSE ä TRUE |
FALSE ä TRUE |
FALSE |
A cam with the following settings is executed: xCamCyclic := FALSE // cam executed once |
|
B |
TRUE |
TRUE |
TRUE |
After one cam cycle, the master axis stops while the setpoint for the slave axis remains unchanged. For a PLC clock cycle,xEndOfProfile is set to TRUE; this means that the cam processing will be completed. |