Overview axis types

Device dialog object

Type

Instance

Description

VirtualAxis

virtual axes

AXIS_REF_VIRTUAL

Virtual axis from PLCDesigner v.4.0

LM_Virtual_Drive

virtual axes

AXIS_REF_VIRTUAL

Virtual axis until PLCDesigner v.3.28

VirtualMaster_Axis

virtual axes

AXIS_REF_VIRTUALM_i900

Virtual axis for i950-TAs with

  • fixed parameter main index (0x500C),

  • fixed-point parameters and

  • reduced number of parameters.

This axis can only be inserted once in a PLCDesigner project for a technology application.

ixxx_Motion_Axis

real axes

AXIS_REF_ixxx

Interface to the real drives.

xxx:Invertertyp i700, i750, i950, i550, ...

Axis Universal Axis AXIS_REF_UNIVERSAL

Universal axis.

If this axis is connected to an EtherCat slave, it behaves like a real axes.

If this axis is not connected to an EtherCat slave, it behaves like a virtual axes.

also see hardware-abstraction