Real axes

The CiA402 device profile is used as interface to the inverters. The state machine of the inverter is controlled via the axis data.

In contrast to virtual axes, real axes come with an actual value channel. Thus, they provide advanced functions.

  • Following error monitoring
  • TouchProbe functionality
  • Brake control
Related topics:

Use of "free encoders"

From all states

Power section inhibited (pulse inhibit)

Power section enabled

CiA402 state machine

Interaction with the PLCopen state machine

CiA402 status

PLCopen status

" Fault "

State change after " ErrorStop "

All states except for " Fault " and " Operation enabled "

State change after " Disabled "

" Operation enabled "

All states are possible except for " ErrorStop " and " Disabled "

  • Exiting the " Fault " (CiA402) state or " ErrorStop " (PLCopen) state is requested by the MC_Reset command.
  • The change to the CiA402 state " Operation Enabled " is made by calling the FB MC_Power with Enable = TRUE. A reset of the Enable input causes the CiA402 " Operation Enabled " state to be quit again.
Operating mode of the axis

The drive behaviour depends on the operating mode selected for the axis (0x6060 or 0x6860 for axis B).

  • Only one operating mode at a time can be active.
  • By default, the "cyclically synchronous position" mode is always active, i.e. the inverter is used as position controller.

The default operating mode of an axis in cyclically synchronous operation can be set in subindex 90 .

The use of the "velocity" (vl) operating mode is only possible in the simple mode of the axis (subindex 27 = 0).

Supported operating modes of the i700 and i950 servo inverters:

0x6060 | 0x6860 - Modes of operation

Info

0

No operating mode

Standstill

2

Velocity mode (vl)

Speed control (closed loop)

This operating mode is only possible in the simple

Mode of the axis (subindex 27 = 0) possible.

8

Cyclic sync velocity mode (csv)*

Speed control with interpolation of the speed setpoint.

9

Cyclic sync torque mode (cst)*

Torque control with interpolation of the torque setpoint.

10

Cyclic sync position mode (csp)*

Position control with interpolation of the position setpoint.

* First, all setpoints are lead over interpolators which divide down setpoint step-changes from the bus cycle to the cycle time of the control loops. All interpolators are parameterised via the "interpolation: time interval" object ( 0x60C2 or 0x68C2 for axis B).